Home › Rinnai › Rinnai Water Heater › Rinnai LC Code: Scale Buildup & Service Reminder — Flush Guide

Rinnai LC Code: Scale Buildup & Service Reminder — Flush Guide

Rinnai Water Heater display showing LC — FixCode Guide error code graphic

Scale build-up in the heat exchanger — the heat exchanger must be flushed; LC0–LC9 count how many 70-hour temporary resets have been used without a flush

LC is the code Rinnai owners in hard-water areas know best, and it is a maintenance alarm rather than a breakdown. It means scale — mineral deposit from hard water — has built up inside the heat exchanger far enough that the heater is protecting itself. Rinnai's wording is consistent across every document: 'LC indicates that there is scale build up in the heat exchanger and that the heat exchanger needs to be flushed to prevent damage. Hard water must be treated to prevent scale build up or damage to the heat exchanger.' Scale damage is pointedly not a warranty defect — the C199 manual's water-quality section states that replacement of a heat exchanger damaged by water quality is not covered. The LC family has a counting system worth understanding. Plain LC (shown in the fault history as 00 — the controller substitutes '00' for 'LC' when you scroll past codes) is the first warning. On newer products a shutdown feature escalates it: the heater will lock out unless reset. The temporary reset — press the ON/OFF button on the temperature controller five times within five seconds — buys 70 hours of operation, after which the heater locks out again with the count advanced: LC1, LC2, and so on. Rinnai's own example decodes it plainly: LC2 means the heater has been reset for three 70-hour periods without a flush and a hard reset. The number on the display is therefore a procrastination counter, and the controller cycles between the set temperature and the LC code, with a beep on Non-SENSEI models, so it cannot be missed. The documented remedy is the flush, and Rinnai publishes the procedure in the owner's manual (section 'Flushing the Heat Exchanger' — 6.3 on SENSEI manuals, 6.2 in the tech sheet references) precisely because it is the one substantial maintenance job the documents hand to a competent owner with the right kit, while many owners still book it as a service. The SENSEI RX/CX flushing procedure's scale-control detail is representative: power and gas off, controller off, hot and cold shutoff valves closed, the pump outlet hose connected to the cold-side service valve, the drain hose on the hot-side service valve, four gallons of undiluted food-grade white vinegar in a bucket, pump and drain hoses into the solution, service valves opened, and the solution circulated through the heat exchanger. Isolation (service) valves are what make this possible without cutting pipe — Rinnai 'strongly recommends' them at installation for exactly this job. After a flush that completes properly, Rinnai states the LC codes reset automatically on RX/CX models. If the code does not clear, the hard reset is a PC-board procedure — the two switches A and B pressed together for five seconds — which returns the LC count to 0. Finally, the prevention half: LC is a water-quality verdict. A heater flushed and returned to the same untreated hard water will count LCs again on the same schedule. Rinnai's repeated sentence — hard water must be treated — means a softener or the model's documented scale-control option, plus the annual service rhythm. Flushing is the repair; treatment is the cure.

Applies to: All Rinnai tankless series. Display and reset details vary by generation: Non-SENSEI (alternating display + beep, power reset on older units, A/B hard reset on newer), SENSEI (00/LC in history), SENSEI RX/CX (automatic clear after a proper flush; flushing history visible in the Rinnai Central app). SS (55) is the separate time-based service reminder covered in this page's FAQs.
Safety first. Before you start: unplug the appliance (or switch off its breaker) before opening any panel, and close the water taps before disconnecting hoses. Rinnai's manuals could not be clearer: if you smell gas, do not light anything, do not touch electrical switches or use a phone in the building — leave, call your gas supplier from outside, and call the fire department if you cannot reach them. All gas-supply, burner, fan, venting, manifold-pressure and internal electrical diagnosis is licensed-professional work; Rinnai restricts its own troubleshooting document to trained and qualified professionals and states that adjusting the internal gas valve voids the warranty. Owner-level work is the outside of the machine: gas and water valves, the vent termination, the condensate drain on condensing models, the inlet water filter, and a single controller reset. Hot exhaust and outlet pipes cause burns; never run the heater with its front panel removed. Keep children and animals away from the unit, keep the area around it clear of combustible materials and stored chemicals, and never use or store gasoline or solvents near any gas water heater.

What causes the LC code on a Rinnai water heater?

Hard water mineral scale in the heat exchanger

The cause, by definition: calcium and lime from hard water deposit on the hottest surfaces inside the heat exchanger, insulating them. Rinnai detects the condition (on RX/CX a dedicated lime-detecting temperature function feeds it) and raises LC before the deposit damages the exchanger. Homes on well water or in known hard-water regions meet LC earliest and most often. The process accelerates itself: a light coating insulates the metal, the metal runs hotter to deliver the same water temperature, and hotter metal precipitates minerals faster, which is why LC intervals shorten when flushes are deferred.

Skipped annual maintenance

The flush LC demands is the same flush the manuals schedule as routine maintenance. A heater that has never been flushed is not unlucky; it is overdue. The LC count then records how long the warning has been deferred in 70-hour increments — which is why a technician reads LC4 very differently from a first LC. The annual rhythm is not arbitrary, either: the manuals bundle the flush with the annual professional inspection, the inlet filter clean and the vent check, so one visit discharges the whole maintenance debt the LC is counting.

Untreated water after previous flushes

Flushing restores the exchanger; it changes nothing about the water. Without treatment — a softener or the scale-control equipment Rinnai documents for the installation — scale re-forms at the same rate and LC returns on the same interval. Repeat LC on a short cycle is a water-treatment conversation, not a flushing-technique argument. Rinnai publishes water-quality limits in the installation manual, hardness and chemistry ceilings the supply must meet, so a treatment recommendation can be checked against printed numbers rather than taken on trust.

Running on temporary resets

The five-press temporary reset exists so a household is not without hot water while a flush is arranged. Used as a lifestyle — reset, 70 hours, reset — it converts a maintenance job into heat-exchanger damage, because the heater is being run deliberately in the condition LC exists to prevent. The escalating LC number is the record of that choice. There is also a warranty edge to the behaviour: the manuals exclude heat-exchanger damage caused by water quality, so a heater run for months on advancing LC counts is being run outside the protection its owner paid for.

A scaled inlet filter and companion restrictions

Scale rarely travels alone: the same water that coats the exchanger loads the inlet water filter with sediment and debris, and the manuals pair the two jobs — the filter is cleaned in the same maintenance rhythm as the flush, and a clogged filter is on Rinnai's list for flow and temperature complaints that accompany an LC history. A heater whose LC arrives together with falling flow or temperature swings is showing the whole water-side picture, and the service that answers it is flush plus filter plus a water-quality conversation, not the flush alone.

Checks to run before you replace anything

  1. Read the exact display: LC, or LC with a digit (LC0–LC9)? The digit is the count of temporary-reset periods already used — note it before doing anything
  2. Scroll the fault history (hold ON/OFF 2 seconds, then UP): LC events appear there as 00 — a history full of 00s is a long scale story, not a new fault
  3. Distinguish LC from SS: SS (or 55) is the time-based 'Service Soon' reminder; LC is the scale-detection alarm. Both end in a flush, but LC is the one that locks the heater out
  4. Check your water: known hard-water supply, well water, no softener or scale control fitted? That context confirms LC rather than questioning it
  5. Look at the installation: are isolation/service valves fitted below the heater? Their presence decides whether the documented pump-and-vinegar flush is straightforward
  6. Note performance symptoms that corroborate scale: rumbling/kettling noises, fluctuating temperatures, longer waits — and check for sibling codes such as 54 (high exhaust temperature from scale hot spots)

Rinnai error code 55 how to fix

  1. Do the flush — it IS the fix: isolate the heater with its service valves and circulate the manual's flushing solution (SENSEI procedure: 4 gallons of undiluted food-grade white vinegar) with a small pump through the heat exchanger, following your model's flushing section step by step
  2. If you do not have isolation valves, a pump kit, or confidence in the procedure, book the flush as a service visit — it is the single most routine tankless service call there is
  3. Temporary running only while the flush is being arranged: press ON/OFF five times in five seconds for up to 70 hours of operation; the controller will keep cycling the LC reminder, and the count will advance if you repeat it
  4. After a properly completed flush, RX/CX models clear LC automatically; if a code remains, the A/B-switch hard reset (both switches, five seconds, count back to 0) is the technician's documented completion step
  5. Clean the inlet water filter as part of the same visit — the manuals pair filter cleaning with flushing in routine maintenance
  6. Prevent the sequel: fit or service water treatment for hard water, and put the flush on the annual calendar — Rinnai's position is that scale damage from untreated water is not a warranty matter

The part that usually fails: The heat exchanger itself — protected, not replaced; plus the inlet water filter and isolation valve kit that make flushing possible

LC is unusual among fault codes in that the 'part' is the component being protected rather than one that failed: the heat exchanger. Rinnai's whole LC system — detection, counting lockouts, published flush procedure — exists to keep scale from destroying it, because a scaled-through exchanger is a replacement, and water-quality damage is excluded from warranty. The supporting hardware matters as much: the inlet water filter (cleaned at the same service) and the isolation/service valve kit, which Rinnai strongly recommends at installation precisely so the flush is a hose-and-pump job instead of a plumbing job. Where prevention is fitted, it is water-treatment/scale-control equipment sized to the home's hardness.

Rinnai error code 55 reset button

LC has three distinct resets and they are not interchangeable. The TEMPORARY reset — ON/OFF pressed five times within five seconds — restarts a locked-out heater for 70 hours per use and advances the LC count; it treats nothing. The AUTOMATIC reset happens on RX/CX models when a flush completes properly: the code clears itself and the flushing history is visible in the Rinnai Central app. The HARD reset — PC-board switches A and B held together for five seconds after flushing — returns the count to 0 when the automatic clear does not happen; Rinnai notes this procedure is not published in the owner's manual, so it is performed by the service technician. Older Non-SENSEI units could clear LC with a plain power off/on. Resetting without flushing, by any route, leaves the scale in place.

The standard owner reset is a controller cycle: close the hot taps, press ON/OFF to turn the controller off, then on again, and run one test draw (code 03's documented form is ON/OFF twice). Special codes have special resets that are not interchangeable: LC and SS use five ON/OFF presses within five seconds (LC's version is a 70-hour temporary reprieve, not a cure); codes 17 and 52 clear only through the PC-board A/B-button sequence ending in 'ECL'; codes 57 and 58 need a hard reset — power off, then on — after the cause is corrected; and the LC hard reset after flushing is the A/B switches held together for five seconds. One reset, then observe: a code that returns is a live fault reporting itself, not a reset that 'didn't take'. Document the outcome of every reset you perform — cleared and held, returned during the draw, or never cleared — because that record is what turns a home reset into diagnostic evidence.

Why does the LC code keep coming back?

Two displays get confused with LC constantly, and this page handles both. SS — also shown as 55 — is 'Service Soon': a purely time-based reminder set at installation (Parameter 03: off, 0.5, 1 or 2 years) meaning service and a flush are due; the heater keeps running, and the reset is ON/OFF five times in five seconds on SENSEI, or holding the PC-board 'A' button until SS disappears on RX/CX. LC, by contrast, is detection-based: the heater has measured a scale condition, counts temporary resets as LC0–LC9, appears in the history as 00, and will lock the heater out. An SS ignored long enough on hard water becomes an LC; an LC is never 'just the reminder'.

Can you still use the water heater with LC showing? Hard-water homes, first LC warnings, LC0–LC9 lockouts, and every 'the heater keeps beeping LC' call — plus SS/55 service-reminder questions, which this page separates from LC.

How to stop LC coming back

When to call a pro. You can reasonably defer a professional for LC longer than for any combustion code — it is a maintenance alarm with a documented owner flush procedure — provided the flush actually happens. Book a technician instead when: there are no isolation valves fitted; the LC count is already high (LC3+) or LC returns within months of a flush (a water-treatment and exchanger-condition assessment); the heater also shows combustion codes; or the unit is under a service plan that includes flushing. Take gas or ignition codes that appear alongside LC seriously in their own right — scale and combustion faults compound.

Retrieving stored fault codes on Rinnai water heaters

Rinnai tankless heaters report faults on the temperature controller — the integrated SENSEI controller or a remote such as the MC-91-2 or MC-601 — as flashing two-digit codes in place of the set temperature. Alongside the numbers sit four letter displays with their own jobs: LC (scale in the heat exchanger, counted as LC0–LC9 when temporary resets are used, and stored as 00 in the fault history), SS (the time-based Service Soon reminder, also shown as 55), FF (a history placeholder recording that maintenance was performed) and, on cascaded commercial systems only, SE. The controller keeps a fault history: turn the heater OFF, hold ON/OFF for 2 seconds and press UP at the same time — the last 9 maintenance codes flash one after the other. A separate performance-data mode (hold DOWN, then ON/OFF) shows live values such as water flow rate (item 01) and outgoing temperature (item 02) — data items, not fault codes.

Other Rinnai water heater error codes

CodeMeaningFirst fix
00Not a live fault — in the controller's maintenance-code history, '00' is substituted for 'LC' (scale build-up)Treat it as an LC: the heat exchanger needs flushing per the manual, and hard water must be treated to stop the scale returning
02No burner operation during freeze protection (Non-SENSEI series)Owner level: confirm power is on (freeze protection needs power) and the gas valve is open. Anything beyond that is licensed-technician work; do not keep cycling the unit in freezing weather
03Power interruption during bath fill — water will not flow when power returnsTurn off all hot water taps, then press ON/OFF twice on the controller. If the code returns after three resets, Rinnai directs you to a professional (PC board suspected)
05Bypass flow control device fault (bypass servo)One power off-and-on cycle is the documented first step. If 05 returns when a hot tap runs, the bypass valve/device is replaced — licensed-technician work
07Circulation flow rate below 2.1 GPM (RH180 hybrid only)Owner level: confirm water supply is on and clean the inlet water filter per the manual. Pump, pressure and flushing work is licensed-technician work
10Air supply or exhaust blockage — on SENSEI condensing models the same code also reports a full condensate trapOwner step: clear the termination, restore the condensate drain (thaw a frozen exposed section, clear a blocked hose end), then make one reset and run a tap
11No ignition — the heater ran its ignition sequence and no flame was established, so it shut down and flashed 11 on the temperature controllerOwner step 1: correct anything external you found — open the closed valve, arrange a propane refill — then make ONE reset attempt (controller OFF then ON, or taps off then on) and run a hot tap
12Flame failure — the burner lit, then the flame was lost during operation and the heater shut downOwner step: with gas supply confirmed and the termination clear, make one controller reset and run a moderate hot-water draw while timing it
13Combustion fault (RH180 hybrid only — not a general tankless code)Licensed-technician work only on the RH180. A standard Rinnai tankless model does not use code 13 — quote the model number when calling for service
14Thermal fuse or overheat sensor (ODS) has activated — heat exchanger overheatingTreat as serious: stop using the heater and call a licensed technician. The bi-metal switch may reset as it cools, but a blown thermal fuse does not — and the overheating cause must be found first
15Venturi control fault (SENSEI and SENSEI RX/CX only)Licensed-technician work: Rinnai's procedure measures the venturi device at the PC board, checks the fan and airflow, then replaces the gas valve assembly or fan as proven
16High outgoing water temperature — safety shutdown, outlet water exceeded 203°F (95°C)Do not keep resetting a heater that has shut down for over-temperature. Airflow obstructions outside can be checked; fan, gas-valve and heat-exchanger work is licensed-technician work
17Venturi blockage — debris is obstructing the venturi on the gas valve/fan assembly (SENSEI and SENSEI RX/CX only)Owner step: restore the condensate drain if it is visibly blocked or frozen at its exposed run, clear the outdoor termination, and record the code — then call; there is no owner reset for 17
18Gas valve adjustment limit (SENSEI RX/CX Smart-Sense gas valve only)Licensed-technician work, and Rinnai directs persistent cases to its technical department. Do not adjust the internal gas valve — Rinnai states adjustment voids the warranty

See the full list on the Rinnai Water Heater error codes hub.

Codes LC gets confused with

10 — Air supply or exhaust blockage — on SENSEI condensing models the same code also reports a full condensate trap Code 10 is Rinnai's airflow fault: the heater cannot move combustion air in and exhaust out the way it needs to, so it shuts down and displays 10.

11 — No ignition — the heater ran its ignition sequence and no flame was established, so it shut down and flashed 11 on the temperature controller Code 11 is Rinnai's no-ignition fault, and it applies across the whole tankless range this site covers: Non-SENSEI models, SENSEI models and the SENSEI RX/CX series all define 11 the same way in Rinnai's Troubleshooting Tankless Water Heater Diagnostic Codes manual.

17 — Venturi blockage — debris is obstructing the venturi on the gas valve/fan assembly (SENSEI and SENSEI RX/CX only) Code 17 is one of Rinnai's narrowest codes: it exists only on SENSEI and SENSEI RX/CX models, and it means exactly what its title says — venturi blockage.

12 — Flame failure — the burner lit, then the flame was lost during operation and the heater shut down Code 12 is the running partner of code 11, and the distinction is the whole diagnosis.

Frequently asked questions

What does Rinnai error code LC mean?

Scale build-up in the heat exchanger. Hard-water minerals have coated the exchanger and it must be flushed to prevent damage. LC is a maintenance alarm, not a failed part — but Rinnai is explicit that scale damage is not covered by warranty, so it should not be ignored.

What do LC0, LC1 and LC2 mean on a Rinnai?

They count deferred maintenance. After the first LC lockout, each temporary reset (ON/OFF five times in five seconds) buys 70 hours and advances the count: LC2 means three 70-hour periods have been used without a flush and a hard reset. The higher the digit, the longer the flush has been postponed.

How do I flush my Rinnai to clear LC?

Follow your manual's 'Flushing the Heat Exchanger' section: power and gas off, close the hot and cold shutoff valves, connect a pump and hoses to the isolation service valves, and circulate the documented solution — the SENSEI procedure uses 4 gallons of undiluted food-grade white vinegar. After a properly completed flush, RX/CX models clear LC automatically.

Can I reset LC without flushing?

Temporarily: five ON/OFF presses in five seconds gives up to 70 hours of running per reset. But no reset removes scale — Rinnai's design counts those resets (LC0–LC9) and locks the heater out again precisely so the flush cannot be deferred forever.

What is the difference between Rinnai LC and SS (55)?

LC is detection: the heater has measured scale in the heat exchanger and will escalate to lockout. SS (shown as SS or 55) is a clock: the installer-set service interval (0.5, 1 or 2 years) has elapsed and service is due. Both are answered with a service and flush, but LC is the urgent one.

Why does LC keep coming back after flushing?

Because flushing cleans the exchanger, not the water. On untreated hard water, scale re-forms at the same rate. Rinnai repeats in every LC text that hard water must be treated to prevent scale build-up or damage — a softener or documented scale-control equipment is the permanent fix.

What is rinnai error code lc?

Scale build-up in the heat exchanger — the heat exchanger must be flushed; LC0–LC9 count how many 70-hour temporary resets have been used without a flush LC is the code Rinnai owners in hard-water areas know best, and it is a maintenance alarm rather than a breakdown.

How to fix rinnai error code lc?

Start here: Do the flush — it IS the fix: isolate the heater with its service valves and circulate the manual's flushing solution (SENSEI procedure: 4 gallons of undiluted food-grade white vinegar) with a small pump through the heat exchanger, following your model's flushing section step by step If you do not have isolation valves, a pump kit, or confidence in the procedure, book the flush as a service visit — it is the single most routine tankless service call there is