Rheem Water Heater Error Codes List: Every Code Explained
Every Rheem water heater error code we could verify against Rheem's own documentation — what it means, what usually causes it, and the first fix to try — in one table. Codes differ between model series, so treat your model's tech sheet as the final word.
How to read and retrieve error codes on Rheem water heaters
Rheem water heaters report faults in three separate languages, and reading the right one is the whole skill. A tank gas heater with an electronic combination gas control has no screen: a single status LED on the control blinks in patterns — 1 flash for normal operation, and 2, 4, 5, 7 or 8 red flashes for faults (Rheem's chart deliberately has no 3- or 6-flash entries). Power-vent models on the IntelliVent control instead use lettered LEDs (A-F) as temperature indicators and error displays. Gas tankless models (RTGH, RTG, IKONIC) show two-digit numeric codes on a built-in display or remote — 11 for no flame detected, 12 for flame lost, P1 for low flow, 1L for scale — and IKONIC units keep a scrollable fault history of recent faults. Hybrid heat-pump and EcoNet smart electric models speak in alphanumeric alarms: press Next until 'Current Alarm' appears, then scroll with the Down arrow; A-codes are shutdown alarms, T-codes are alerts. Electric tankless models on the RTEX/EcoSmart platform use short E-codes (E1-E5). Always identify the platform before looking a code up: the same characters mean different things in different languages.
The complete Rheem water heater error code list
| Code | Meaning | Most likely cause | First fix |
|---|---|---|---|
| 00 | Tankless (older RTG generation): the unit has run 1 hour of continuous combustion and shuts down as a safety limit. It is a run-time protection, not a part failure. | A hot tap, recirculation pump or leak kept the burner firing continuously | Close all hot taps, switch off any recirculation pump, let the unit rest, then run a tap briefly to confirm normal cycling. |
| 1 flash | Tank gas (electronic combination gas control status LED): 1 flash every 3 seconds — blue on newer controls — means NORMAL OPERATION. The pilot is lit and the control is satisfied. | No fault — this is the healthy heartbeat of the control | Nothing to fix. If you have no hot water but see 1 flash, look at demand, temperature setting and tank issues instead of the control. |
| 1L | Tankless: lime (scale) buildup warning in the heat exchanger. This is the code often mis-copied as 'iL' — Rheem's code is the digit one followed by L. | Mineral scale insulating the heat exchanger, usually in hard-water homes without flushing | Flush/descale the heat exchanger with the isolator valves and a pump, or book a descale service; then clear the warning. |
| 2 flashes | Tank gas (combination gas control status LED, red): thermopile voltage low, with the pilot still lit. The control is warning that the pilot assembly is barely making enough millivoltage to run. | Weak/dirty pilot flame, a failing thermopile, or a loose thermopile connector or damaged wires | Rheem's chart directs: check the thermopile connector and wires at the control and inspect the pilot assembly — pilot and thermopile work is technician work if cleaning access is not obvious. |
| 03 | Tankless: manifold / EZ-Link control problem — on linked (manifolded) units the control cannot coordinate the heaters; Rheem Australia lists 03 as the EZ Link code. | Manifold controller (MIC-180 / EZ-Link) communication or setting failure | Power the system down and back up once; manifold wiring and controller settings are technician work. |
| 4 flashes | Tank gas (combination gas control status LED, red): high temperature shutdown — the high water temperature limit has tripped and the control has shut the burner down. | Water temperature exceeded the limit (failed thermostat sensing, overheating, or a genuine over-temperature event) | Rheem's chart says this needs a qualified service technician. Do not relight and force-run a heater that has tripped its high limit. |
| 05 | Tankless: on RTGH and Rheem Australia models, imperfect combustion — the air intake or vent exhaust is blocked or the vent pipes are not connected properly. In Rheem's IKONIC-era troubleshooting manual, 05 is instead a warning for low heat-exchange temperature. Check which manual matches your model. | Blocked air intake / exhaust, disconnected venting, or (IKONIC generation) a cold heat exchanger | Keep 12 in (30 cm) of clearance at the air intake, confirm vent pipes are connected and clear; if it persists, book service. |
| 5 flashes | Tank gas (combination gas control status LED, red): water temperature sensor failure — the control can no longer trust its temperature sensing. | Failed temperature sensor in the control/valve assembly | Qualified service technician per Rheem's chart; on these integrated controls the repair is usually control replacement. |
| 07 | Tankless, WiFi models only: warning for a limited hot water condition — the heater is restricting flow because water-saving mode is active on the WiFi controller. | Water-saving mode limiting flow through the WiFi app/controller | Turn water-saving mode off in the app if full flow is needed; no part is faulty. |
| 7 flashes | Tank gas (combination gas control status LED, red): combination gas control / gas valve failure — the electronic gas control itself has faulted internally. | Internal failure of the combination gas control (thermostat/gas valve unit) | Qualified service technician per Rheem's chart. There is no owner reset for a 7-flash control failure; expect control replacement. |
| 8 flashes | Tank gas (combination gas control status LED, red): flame sense error — newer Rheem manuals word it as a false pilot flame signal: the control senses flame when there should be none. | Flame-sensing fault in the control, or a genuine out-of-sequence pilot/flame condition | Qualified service technician per Rheem's chart; a flame signal out of sequence is a safety fault, not a relight-and-see item. |
| 10 | Tankless: air supply or exhaust problem. The IKONIC-era manual calls 10 a warning for incorrect inlet air volume (unit run before venting was finished, or the blower is not moving enough air); the older RTG manual lists air supply or exhaust blockage. | Blocked or disconnected venting, blocked termination, or a weak blower motor | Inspect both vent terminations and clear any blockage; blower testing is technician work. |
| 11 | Rheem tankless (RTGH / RTG / IKONIC): flame not detected by the flame rod. At ignition the unit tries to light twice, and if the flame rod never proves a flame, it shuts down and displays 11. The RTGH service chart gives the classic owner-level cause: the gas shut-off valve is not fully opened. | Gas shut-off valve not fully open, or gas supply interrupted | Open the gas shut-off valve at the heater completely, and restore any interrupted supply (refill or replace the LP tank if it is empty). |
| 12 | Rheem tankless (RTGH / RTG / IKONIC): flame detected, then lost. The burner lit and the flame rod proved flame, but the flame dropped out during operation; Rheem's manual states the unit counts these flame-loss incidents and displays 12 after 3 consecutive losses. The RTGH service chart gives the plain-language causes: gas service interrupted, or LP gas running low. | LP gas running low, or gas service interrupted | Refill or replace the LP tank if the gauge is low, or confirm with the gas utility that service is not interrupted. |
| 13 | Tankless (indoor RTG-generation units; also a hard-lockout code on IKONIC-era units): the flame rod is detecting poor or improper combustion, commonly from inadequate gas supply and/or venting. Five shutdowns from 13 within 4 hours force the full reset procedure. | Poor combustion from gas supply or venting problems; wrong altitude (DIP2) setting; fouled flame rod | Confirm exhaust cannot recirculate into the intake, clear vent blockages and check the altitude setting; gas and flame-rod work is for a licensed technician. |
| 14 | Tankless: the overheat limiter (OHL) has activated / the overheat wrap safety circuit has tripped. Rheem's manual states this is normally caused by inadequate or wrong gas supply and/or venting. | Overheating from wrong gas supply, venting faults, or a damaged overheat limiter | Do not keep resetting it — an overheat safety has tripped. Turn the unit off and call a licensed technician. |
| 15 | Tankless: excessively hot water detected — Rheem's manual defines it as outlet and/or heat exchanger water temperature above 207 F (97 C) for more than 15 seconds (the boiling safety device on RTG-generation units). | Sediment/scale in the heat exchanger, vent blockage, gas supply pressure fault, or a failing thermistor | Stop using the unit and call a licensed technician — this is an over-temperature safety shutdown, and the water is a scald risk. |
| 16 | Tankless: outlet temperature fault. In Rheem's IKONIC-era manual, 16 means the outlet water temperature is above the set point and the outlet thermistor must be checked first; Rheem Australia lists 16 as outlet water temperature sensor failure. | Failed outlet thermistor, or a faulty water bypass valve/motor | Thermistor resistance testing and replacement are technician work; note the code and whether the water ran hotter than set. |
| 17 | Tankless, WiFi models only: WATER LEAK DETECTED inside the water heater by the leak sensor. Despite appearing on 'combustion code' lists, Rheem documents 17 purely as a leak code — it has nothing to do with the burner. | An internal leak (heat exchanger or water valve), or condensation collecting in the cabinet / entering from the intake venting | Turn the power off, close the water shutoff, and look for water in and under the unit. Do not just clear it — find the water source or call a plumber. |
| 21 | Tankless (older RTG generation): malfunction of the air intake filter switch — the control cannot confirm the air filter door / front panel is in place. | Front panel or air filter cover not seated correctly, or a failed filter switch | Refit the front panel and seat the air filter cover firmly; if the code stays, the switch needs a technician. |
| 24 | Tankless: control/switch fault. Rheem Australia lists 24 as an operational switch fault; in the IKONIC-era manual, 24 appears when the UP/DOWN buttons on the controller are held for more than 20 seconds. | Faulty operational switch or controller, damaged remote wiring, or buttons held down accidentally | Power off, unplug, disconnect and reconnect the remote wires, then power up; a repeat 24 means replacing the controller (technician). |
| 28 | Tankless (IKONIC-era manual): warning for low heat-exchange temperature — the heat exchanger is running colder than the control expects. | Scale buildup on the heat exchanger thermistor, a failing heat exchanger thermistor, or a control board fault | Book service: the manual's flow is thermistor cleaning/testing, then thermistor or control board replacement. |
| 29 | Rheem tankless, and the meaning depends on generation. On condensing IKONIC-era models: condensation is not draining from the collector — the built-in drain trap's electrode reports the trap full or unreadable. On RTGH condensing models the service chart says the neutralizer is clogged. On older RTG and Rheem Australia models, 29 meant heat exchanger outlet temperature too low. Identify your model before acting. | Protection plug left in the drain connection | Remove the protection plug from the drain connection at the bottom of the unit if it is still fitted. |
| 31 | Tankless: inlet (cold water) thermistor malfunction — Rheem Australia lists 31 as the inlet thermistor open circuit. | Failed inlet thermistor, scale on the sensor, or a loose/damaged connector or harness | Technician work: the manual tests thermistor resistance (7K-23K ohms) and replaces the sensor or control board as needed. |
| 32 | Tankless: heat exchanger thermistor malfunction (open circuit in the Rheem Australia chart). | Failed or scaled heat exchanger thermistor, or its wiring | Technician work: resistance-test the thermistor; clean scale from it or replace it. |
| 33 | Tankless: outlet (hot water) thermistor malfunction (open circuit in the Rheem Australia chart). | Failed or scaled outlet thermistor, or its wiring | Technician work: resistance-test the outlet thermistor and replace it if out of range. |
| 34 | Tankless: ambient / air supply thermistor malfunction (open circuit in the Rheem Australia chart). | Failed inlet-air/ambient thermistor, debris on the sensor, or its wiring | Technician work: clean debris from the sensor, resistance-test it, replace if faulty. |
| 35 | Tankless: improper thermistor connection — the thermistor connections are crossed or wrongly landed (Rheem Australia: thermistor connections crossed). | Thermistor leads connected to the wrong positions, usually after a repair | A technician should trace and correct the thermistor wiring against the manual's connector chart. |
| 48 | Tankless, WiFi models only: warning that water leak detection has been disabled — after a 17 leak code is suppressed in the WiFi app for 24 hours, the unit displays 48. | Leak detection was switched off in the app following a 17 code | Treat it as a reminder: confirm there is genuinely no leak, then re-enable leak detection in the app. |
| 49 | Tankless, WiFi models only: warning that the water leak sensor is not installed while a WiFi controller is in use. | Leak sensor missing, disconnected, or never fitted | Have the leak sensor installed/connected so 17 leak detection can work; the heater still runs, but unprotected. |
| 51 | Tankless: main gas solenoid valve (SV) malfunction — Rheem Australia lists 51 as gas cut-off malfunction (SV0). | Failed gas solenoid valve or its drive circuit | Gas valve work is licensed-technician only. Turn the unit off and book service. |
| 52 | Tankless: proportional gas valve malfunction (Rheem Australia: P.G.F.R. control failure) — the modulating gas control is not regulating correctly. | Failed proportional gas valve / gas flow regulator control | Licensed technician only — do not attempt gas valve adjustment or replacement yourself. |
| 56 | Tankless (Rheem Australia chart): bypass solenoid failure — the water bypass control solenoid has failed. | Failed bypass solenoid valve | Book service for solenoid testing and replacement. |
| 61 | Tankless: blower (fan) motor fault — the RTGH chart groups 61 with 99 as a faulty blower motor; the IKONIC-era manual defines 61 as blower motor speed incorrect for combustion. | Failing combustion fan/blower, blocked venting loading the fan, or fan wiring | Check the vent terminations are clear from outside; fan replacement is technician work. |
| 65 | Tankless: water flow control fault — the RTGH chart lists 65 as a faulty water flow solenoid; Rheem Australia lists it as a malfunction of the water volume control motor. | Failed water flow solenoid / water volume control motor | Book service; the flow-control assembly is internal and not owner-serviceable. |
| 66 | Tankless: bypass motor / water bypass control failure — the motor that blends bypass water to trim outlet temperature has failed. | Failed bypass motor or its wiring | Technician work: the manual routes 16-temperature complaints and 66 to the same bypass assembly tests. |
| 70 | Tankless (IKONIC-era manual): microcomputer abnormality — the control board's processor has faulted. | Control board failure, power surge damage | Try one power cycle (unplug, wait, reconnect). A returning 70 means a replacement control board. |
| 71 | Tankless: solenoid valve drive circuit failure (Rheem Australia: G.I.S. valve control failure). | Failed control board gas-valve drive circuit | Licensed technician — the fix is control board diagnosis/replacement, not a gas part you can swap. |
| 72 | Tankless: false flame — the flame rod detected a flame signal before ignition, when no flame should exist. | Flame rod short/contamination, control board fault, or a genuine flame present out of sequence | Stop and call a licensed technician: a flame signal out of sequence is a safety fault, not a reset-and-see code. |
| 73 | Tankless (RTG generation / Rheem Australia): vent type control data failure — the control's stored vent-configuration data is invalid. | Control board data/configuration fault | Technician work: vent-type settings and board configuration must be checked against the installation manual. |
| 74 | Tankless (Rheem Australia chart groups 74/75/76): communication problem between the remote controller and the water heater. | Damaged or loose remote-control wiring, or a failed remote | Check the remote cable run for damage and tight terminals; if wiring is sound, the remote or board needs service. |
| 76 | Tankless: communication failure between the built-in display/remote controller and the heater (also one of the Rheem Australia 74/75/76 communication group). | Loose or damaged remote wiring, failed remote controller, or control board fault | Power down, reseat the remote connections, power up; persistent 76 is a service call. |
| 77 | Tankless, WiFi models only: warning for WiFi chip communication failure — communication between the WiFi chip and the display microcontroller is lost. | WiFi display/chip fault | Power-cycle the unit once; if 77 returns, the WiFi display assembly needs service. Heating itself is not the fault. |
| 79 | Tankless: blower (fan) motor current detection failure — the control cannot read the fan motor's current correctly. | Failing fan motor or its current-sensing circuit on the control board | Technician work: fan and board testing with the manual's flow chart. |
| 80 | Tankless: flame was still detected after the solenoid valves closed — Rheem Australia lists 80 as gas cut-off defective. | Gas valve not sealing (cut-off defective), or a flame-sensing fault | Safety fault: turn the gas shutoff to the unit off and call a licensed technician immediately. |
| 81 | Tankless (Rheem Australia chart): no false flame detected where the sequence expected one — part of the gas cut-off safety checks. | Flame sensing or gas cut-off circuit fault | Licensed technician — this belongs to the same safety family as 72 and 80. |
| 82 | Tankless: installed gas chip error — the gas-type chip fitted does not match the unit's configuration (Rheem Australia: functional problem on the gas type circuit board). | Wrong or faulty gas chip / gas-type board after a conversion or board swap | Technician only: the gas type (NG vs LP) configuration must be verified before the unit runs again. |
| 83 | Tankless, WiFi models only: warning for configuration data restore failure — the WiFi display's microcontroller cannot read its stored data. | WiFi display memory fault | Power-cycle once; a persistent 83 points to the WiFi display assembly (service item). |
| 84 | Tankless, WiFi models only: warning that the configuration write limit of the display's memory (EEPROM) has been exceeded. | Worn display memory from excessive setting writes | Service item: the WiFi display assembly is the documented check point. |
| 85 | Tankless, WiFi models with recirculation only: warning that the DIP switch recirculation setting on the control board does not match the WiFi app setting. | DIP switch and app recirculation settings disagree | Have the installer align the board DIP setting with the app setting; do not flip DIP switches at random. |
| 88 | Tankless: maintenance notice — the RTGH chart defines 88 as the reminder to flush the heat exchanger and replace the water treatment filter if fitted. | Service interval reached; scale control is due | Flush/descale the heat exchanger (or book it done), then clear 88 with the manual's button procedure: remote on, gas and water shutoffs off, press DOWN to the lowest temperature, hold DOWN + UP for 5-10 seconds, restore gas and water. |
| 89 | Tankless: high exhaust temperature — the over-temperature limit switch on the secondary heat exchanger has activated. | Excessive exhaust temperature from venting faults, scale, or over-firing | Over-temperature safety: switch off and call a licensed technician. |
| 90 | Tankless: vent blockage detected BEFORE ignition, during the pre-purge cycle. | Blocked or disconnected intake/exhaust venting, blocked termination, unit run before venting was installed | Clear both vent terminations and confirm all vent joints are connected; if the vents are genuinely clear, the blower needs testing. |
| 92 | Tankless condensing (RTGH chart): the neutralizer needs replacement soon — the unit can still be used for a while. | Condensate neutralizer media is exhausted | Arrange neutralizer replacement; do not ignore it until it becomes 93. |
| 93 | Tankless condensing (RTGH chart): the neutralizer must be replaced — the unit cannot be used until it is. | Neutralizer media fully exhausted / neutralizer at end of life | Replace the neutralizer (or have it replaced) before running the heater again. |
| 99 | Tankless: vent blockage detected AFTER shutdown, during the post-purge cycle (the RTGH chart also groups 99 with 61 for a faulty blower motor). 99 is one of the hard-lockout codes cleared by the DIP-switch reset procedure. | Blocked venting found at post-purge, or a failing blower motor | Clear the vent terminations first; if vents are clear, book blower testing — repeated 99 lockouts need the documented reset procedure, not guesswork. |
| A001 | Triton commercial smart tank (gas): ignition lockout — after 9 consecutive failed ignition attempts the heater disables itself until cleared. | Repeated ignition failure: gas supply, igniter, flame sensing or venting faults | The manual clears it by turning the unit off and back on, but 9 failed ignitions mean a real fault — book a commercial service technician. |
| A002 | Triton commercial smart tank (gas): flame-not-stable lockout — the flame was lost 3 times within a single heat cycle, so the heater locked out. | Unstable flame from gas pressure, venting, or a degraded flame rod | Reset once via power off/on per the manual; if it recurs, flame and gas checks are technician work. |
| A003 | Triton commercial smart tank (gas): intake pressure switch open while the blower is running — airflow proving has failed on the intake side. | Blocked intake, pressure switch or tubing fault, or blower problem | Check the intake termination for blockage; pressure-switch diagnosis is technician work. |
| A004 | Two Rheem platforms use A004 differently — HYBRID heat pump: compressor shutdown from a discharge-to-suction pressure trip. TRITON commercial tank: proof-of-airflow switch open during heating. Read the label on your unit before acting. | Hybrid: refrigerant-side trip or airflow restriction. Triton: airflow proving switch open during a heat cycle | Hybrid: check the air filter screen and airflow first. Triton: check intake/exhaust for blockage. Either way, a repeat A004 is a service call. |
| A005 | Two Rheem platforms use A005 differently — HYBRID heat pump (and its T005 alert twin): compressor shutdown, discharge temperature high; the heater falls back to electric elements, and Rheem's checks are fan operation, a clean filter screen, and signs of refrigerant leak. TRITON commercial tank: proof-of-airflow switch open during pre-purge. | Hybrid: low airflow over the evaporator, a stopped fan, or low refrigerant. Triton: airflow switch not proving at pre-purge | Hybrid owners: clean the filter screen and confirm the fan runs and air moves freely around the unit. If A005 returns, the refrigerant side is sealed-system work for a technician. |
| A006 | Hybrid heat pump: suction temperature too low — the compressor's suction side has run colder than allowed and the compressor has shut down. | Low airflow, very cold ambient air around the unit, or a refrigerant-side problem | Confirm the filter screen is clean and the unit has the air volume its manual requires; persistent A006 is a sealed-system service call. |
| A007 | Triton commercial smart tank (gas): exhaust flue pressure switch open during heating — exhaust-side airflow proving has failed mid-cycle. | Blocked flue/exhaust, pressure switch or tubing fault | Check the flue termination for blockage from outside; switch diagnosis is technician work. |
| A008 | Hybrid heat pump: dry fire detected — the heater believes the tank is not full of water and disables heating to protect the elements. | Tank not completely filled, or air trapped in the tank after plumbing work or a refill | Fill the tank completely and purge air by running a hot faucet until water flows steadily, per the manual; do not energise a dry tank. |
| A009 | Hybrid heat pump (alert twin T009): compressor wiring may be faulty — the control has detected a compressor wiring problem. | Compressor wiring or connection fault | Book service: compressor wiring is internal, high-voltage work. |
| A100 | Smart electric tank (Performance Platinum LCD models): lower temperature thermistor failure — the lower tank temperature sensor has failed. | Failed lower thermistor or its wiring | Call for service: the sensor is internal; the heater cannot regulate the lower tank correctly without it. |
| A101 | Two Rheem platforms use A101 differently — HYBRID heat pump: suction temperature sensor failure. SMART ELECTRIC tank: upper temperature thermistor failure. | A failed temperature sensor (suction sensor on hybrid; upper tank thermistor on smart electric) or its wiring | Book service for sensor testing/replacement on either platform. |
| A102 | Two Rheem platforms — HYBRID heat pump: ambient temperature sensor failure. SMART ELECTRIC tank: water sensor alarm — water has been detected in the drain pan by the leak sensor. | Hybrid: failed ambient sensor. Smart electric: a leak, a weeping fitting, or condensate reaching the pan sensor | Smart electric owners: find the water source first — dry the sensor and pan only after confirming nothing is leaking. Hybrid: sensor replacement is a service item. |
| A103 | Two Rheem platforms — HYBRID heat pump: lower heater temperature sensor failure, and the heater is disabled. SMART ELECTRIC tank: fill the tank with water — the control believes the tank is not full. | Hybrid: failed lower tank sensor. Smart electric: tank not full / air in the tank after filling or plumbing work | Smart electric: fill the tank fully, purge air at a hot faucet, then recycle power. Hybrid: the disabled heater needs sensor service. |
| A104 | Two Rheem platforms — HYBRID heat pump: upper heater temperature sensor failure. SMART ELECTRIC tank: emergency cut-off (ECO) alarm — the high-limit ECO has tripped. | Hybrid: failed upper tank sensor. Smart electric: an over-temperature event tripping the ECO | Smart electric: the manual's route is resetting the ECO or calling service — an ECO trip means the water overheated, so treat it seriously. Hybrid: sensor service. |
| A105 | Two Rheem platforms use A105 differently — HYBRID heat pump: evaporator temperature sensor failure (the sensor that watches the outdoor coil). SMART ELECTRIC tank: lower element error — the lower heating element or its wiring/connections are faulty, and the manual says to call for service. | Hybrid: failed evaporator sensor. Smart electric: burned-out lower element or a wiring/connection fault | Neither is an owner repair: element and sensor work means power off, tank access, and a service visit. Tell the technician which platform and which A105 meaning applies. |
| A106 | Two Rheem platforms — HYBRID heat pump: discharge temperature sensor failure. SMART ELECTRIC tank: upper element error. | Hybrid: failed discharge sensor. Smart electric: failed upper element or its wiring | Service call on either platform; elements and sealed refrigerant-side sensors are not owner parts. |
| A107 | Two Rheem platforms — HYBRID heat pump: water detected on the floor by the leak (rope) sensor; the manual allows a 24-hour override by holding Clear Alarm for 5 seconds, only while you deal with the leak. SMART ELECTRIC tank: element wire routing error. | Hybrid: a real leak, or the rope sensor sitting in incidental water. Smart electric: element wiring landed incorrectly | Hybrid: find and fix the water source — never use the 24-hour override to ignore a leak. Smart electric: wiring correction is service work. |
| A108 | Two Rheem platforms — HYBRID heat pump: condensate blocked; the manual's instruction is to unclog the condensate line. SMART ELECTRIC tank: lower element relay stuck on (control board replacement). | Hybrid: blocked condensate drain. Smart electric: a welded/stuck relay on the control board | Hybrid owners can clear the condensate line themselves. Smart electric: a relay stuck ON is a safety fault — power off at the breaker and call service. |
| A109 | Smart electric tank (Performance Platinum LCD models): upper element relay stuck on — the control board relay is not switching off (compare A108 for the lower relay on the same platform). | Welded relay on the electronic control board | Power off at the breaker and call service; a stuck-on relay can keep heating past the set point. |
| A110 | Smart electric tank (Performance Platinum LCD models): lower temperature conversion error — the control cannot convert the lower sensor's reading. | Sensor signal or control board conversion fault | Service call: on the Gladiator-style blink chart these conversion errors sit in the control/power-board fault family. |
| A111 | Smart electric tank (Performance Platinum LCD models): upper temperature conversion error — the control cannot convert the upper sensor's reading. | Sensor signal or control board conversion fault | Service call, as with A110; expect sensor and control board testing. |
| A112 | Triton commercial smart tank: shutoff valve not open — the automatic shutoff valve has not opened, and heating is disabled. | Shutoff valve closed, failed, or not responding to the control | Confirm the water supply to the building/unit is on; valve diagnosis on a commercial unit is a service call. |
| A120 | Hybrid heat pump / EcoNet family: shutoff valve error (the manual lists a family of shutoff valve errors, A120-A123) — the automatic water shutoff valve is not operating as commanded. | Shutoff valve fault, blockage, or wiring problem | Check for anything physically blocking the valve and confirm water supply; valve replacement is a service item. |
| A125 | Hybrid heat pump with electric backup: lower element error, or the lower element relay is stuck closed. | Failed lower element, or a relay welded shut on the control | Breaker off and book service — a relay stuck closed can heat uncontrolled. |
| A126 | Hybrid heat pump with electric backup: upper element error, or the upper element relay is stuck closed. | Failed upper element, or a relay welded shut on the control | Breaker off and book service, as with A125. |
| A127 | Hybrid heat pump with electric backup: element wire routing error — the element wiring does not match the expected routing. | Element leads landed on the wrong terminals, typically after an element or board replacement | Service work: wiring must be corrected against the unit's wiring diagram before it heats again. |
| A128 | Hybrid heat pump with electric backup: element relay failure to close (A128/A129 cover the two element relays) — the relay never switches the element on. | Failed relay or control board output | Service call; the symptom is usually slow recovery or lukewarm water rather than a safety risk. |
| A130 | Hybrid heat pump: unit off because the air temperature is at freezing — the heat pump will not run its compressor in freezing air. | Ambient air around the unit at/below freezing (unheated space in a cold snap) | This is protective behaviour, not a broken part: restore the space temperature or rely on backup heat until the air warms, per the manual for your model. |
| A200 | Hybrid heat pump: high water temperature — the ECO high-limit has tripped and the heater is disabled. | A genuine over-temperature event in the tank | Heater stays disabled until serviced: an ECO trip means the primary controls failed to stop heating. Breaker off, call service, and treat stored water as a scald risk. |
| CL | Tankless remote display: NOT a fault code. CL is the confirmation the remote flashes (then shows solid) during Rheem's DIP-switch reset procedure to show the fault history has been cleared; the companion reset confirmation is UL. | A technician or owner has just run the reset / clear-fault-history procedure (used for hard lockouts such as 10, 13 and 99) | Nothing to fix: release the MIN/MAX buttons, turn the remote back on, and run a hot tap to confirm normal operation. |
| E1 | Electric tankless (EcoSmart/RTEX platform): inlet thermistor fault — the incoming-water temperature sensor is reading out of range or has failed. | Failed inlet thermistor or its connection | Turn the breakers off and book service: thermistor testing/replacement is internal work on a high-amperage appliance. |
| E2 | Electric tankless (EcoSmart/RTEX platform): outlet thermistor fault — the heated-water temperature sensor is reading out of range or has failed. | Failed outlet thermistor or its connection | Breakers off and book service; do not run the unit on a failed outlet sensor, because it is part of overheat protection. |
| E3 | Electric tankless (EcoSmart/RTEX platform): both thermistors fault — inlet and outlet temperature sensors are both faulting at once. | Both thermistors failed, a shared harness/connector problem, or a control board fault | Breakers off and book service; two simultaneous sensor faults usually point at wiring or the control, not two dead sensors. |
| E4 | Electric tankless (EcoSmart/RTEX platform): high temperature — the unit has detected excessively hot outlet water and shut down to protect you. | Flow too low for the power applied, a failing thermistor, or scale restricting the heat exchanger | Let the water cool, check for a clogged inlet filter and adequate flow; if E4 returns, book service — never bypass an overheat shutdown. |
| E5 | Rheem electric tankless (EcoSmart / RTEX platform): high flow rate. The water is moving through the heater faster than its elements can bring it to the set temperature, so the outlet runs lukewarm and the control reports E5. EcoSmart's troubleshooting guide — EcoSmart is Rheem's electric tankless division — lists E5 simply as 'high flow rate': a capacity report, not a failed part. | Too many fixtures drawing at once | Reduce simultaneous demand: stagger the big draws (laundry, tub, showers) until you know the unit's comfortable ceiling. |
| No light | Tank gas (combination gas control status LED): no light at all means the control is turned off or the pilot is not lit — usually because the thermopile is making insufficient millivoltage to power the control. | Pilot out, failed thermopile, or the control knob turned off | Relight the pilot per the label instructions; if it will not light or stay lit, the thermopile/pilot assembly needs a technician. |
| P1 | Tankless: not enough water flow for operation — flow through the unit is below what the heater needs to fire and run correctly. | Low incoming water pressure, a clogged inlet water filter/screen, partly closed valves, or too-small demand at a single low-flow fixture | Clean the inlet water filter at the cold inlet, confirm inlet valves are fully open, and open the hot tap further; if flow is still weak everywhere, check the home's water pressure. |
| S103 | Electric tankless (EcoSmart/RTEX platform): low voltage — the supply voltage reaching the unit is below what it requires. | Undersized or failing breaker/wiring, a loose connection, or low utility voltage | This is an electrician's job: supply wiring and breaker sizing on these units carry very high current and are not owner-serviceable. |
| Steady light | Tank gas (combination gas control status LED): a constantly lit LED means the pilot has recently extinguished and the thermopile is still cooling down — the control is not yet ready to relight. | Pilot recently went out (draft, thermopile weakening, gas interruption) | Wait for the LED to go out, then follow the lighting instructions on the heater's label; a pilot that will not stay lit needs a technician. |
| T113 | Triton commercial smart tank: flame rod degraded alert (T113/T114 are the alert pair; the matching alarm family covers the same sensor) — the peak flame rod current has drifted from its startup average. | Flame rod fouling or wear | The manual's route is to clean and inspect the flame rod, replacing it if cleaning does not restore it — technician work on a commercial burner. |
| T131 | Hybrid heat pump: clean filter reminder — a maintenance alert (T-codes are alerts, not shutdown alarms) telling you the air filter screen is due for cleaning. | Filter cleaning interval reached | Wash the filter screen, let it dry, refit it, and clear the reminder — this one is genuinely owner-level. |
| T132 | Hybrid heat pump: the water heater is having difficulty satisfying demand — an alert that hot water use is outrunning the heat pump's recovery. | Very high demand, very cold inlet air/water, or a heat pump already carrying another fault | Check for other active alarms first; if none, consider a higher-recovery mode during peak use and confirm the filter screen is clean. |
| T300 | Hybrid heat pump: water leak sensor not installed — an alert that the unit's leak detection sensor is absent, so leak alarms cannot protect the installation. | Leak sensor never fitted, removed, or disconnected | Have the sensor installed/connected; until then the unit heats normally but cannot warn you about water on the floor. |
How to reset / clear error codes on Rheem water heaters
Each Rheem platform resets the way its manual documents, and only that way. Tankless models: close the hot faucet, turn the controller off, switch off the electrical supply, wait 5 minutes, restore power, turn the controller on, and open a hot tap; IKONIC displays also clear alarms via ENTER and 'Clear Alarms?' — Yes; hard lockouts (10, 13, 99) have a DIP-switch procedure that ends with the remote flashing CL (fault history cleared) or UL (reset confirmed). Tank gas controls have no reset button: the status LED clears when the underlying fault clears, and Rheem's chart routes 4, 5, 7 and 8 flashes straight to a qualified technician. Hybrids and smart electric tanks: read and note the alarm first (Next / Down arrows on the hybrid display), fix the cause, then clear; a leak alarm such as A107 can be overridden for 24 hours only by holding Clear Alarm for 5 seconds — time bought to arrange the repair, not to skip it. One reset after fixing the cause is the documented pattern on every platform; repeated resets against a live fault are not a strategy.
How to diagnose any Rheem water heater code
Work the problem in this order — and stop wherever gas piping, the burner compartment, venting or the temperature-and-pressure relief valve begins, because those belong to a licensed technician: (1) record the report exactly — a counted LED flash pattern, a numeric display code, or a smart-control alarm are three different languages, and a photograph or video beats a memory of any of them; (2) establish the water story: is there no hot water at all, water that runs cold mid-draw, or water but with a code — tankless codes split into ignition, flame, airflow/venting, flow and temperature families, and tank codes into ignition, sensor and control families, and the family picks the checks; (3) run the owner-level external checks for that family first: power and the unit's switch, the gas cock fully open, intake and exhaust terminations clear of snow, nests and debris, the inlet water filter or screen rinsed (tankless), the condensate trap and drain not blocked or frozen (condensing models), and on tank models the status light read before anything is reset; (4) reset once, the way the brand documents, and run hot water at one tap while you watch — a code that returns at the same stage (fan start, ignition click, flame light, sustained burn) is an active fault naming its stage, not a glitch; (5) everything past that line — flame sensors and igniters inside the burner, gas valves, heat exchangers, control boards — is professional work with the gas supply and a meter involved. Two standing cautions: never plug or cap a dripping T&P relief valve (it is reporting pressure or temperature, and it is the tank's last safety device), and treat any gas smell as an emergency — leave and call the gas utility. Scalding is the quiet hazard in every reset: a control fault that lets outlet temperature drift high is a reason to stop using the water on skin until the code is resolved.
Three display languages under one brand
The single most useful fact about Rheem water heater codes is that the brand speaks three unrelated languages, and a code is meaningless until you know which language your heater speaks. Tank gas heaters with the electronic combination gas control have no display: a single LED blinks a count — one flash is health, seven is a dead control. Tankless heaters show two-digit numbers with decimal-family meanings (11 and 12 are the flame pair; 92 and 93 are neutralizer life). Hybrids and smart electrics show letter-number alarms where A005 can mean a compressor discharge trip on a heat-pump model or an element fault's neighbour on a commercial tank — and where the same number on a different platform is not a variation but a completely different sentence. Before searching any code, name your platform out loud: tank gas blink, tankless numeric, hybrid/EcoNet alarm, or electric-tankless E-code. Half of all wrong internet answers about Rheem codes come from reading the right code in the wrong language. That is why the hub table for this brand prints the platform inside every row's meaning: five seconds spent naming the platform saves hours spent chasing the wrong system's fault.
Alarms, alerts, and warnings are not the same word
Rheem's newer platforms grade their messages, and the grade tells you how to respond. On hybrid and Triton models, codes beginning with A are alarms: the heater has shut something down — a compressor, an element, or the whole unit — and will stay shut down until the cause is fixed. Codes beginning with T are alerts: the heater still runs, but it is telling you something is drifting (a flame rod degrading, a filter due for cleaning, demand outrunning recovery). Tankless models draw the same line between error codes, which stop the unit, and warning codes such as 05, 07, 10, 48, 49 and 88, which flag conditions — maintenance due, a sensor not installed, leak detection disabled — while heating continues. Read the grade before the number: a T-code or warning is a scheduling task, an A-code or error is a stop-and-fix task, and confusing the two either creates panic over a filter reminder or complacency about a disabled heater. When you report a code to a technician or a parts desk, report the grade with it: an A-code sends the conversation toward a shutdown diagnosis, a T-code toward maintenance — correctly different directions.
The fault history is the diagnosis you already paid for
Rheem's tankless controls remember. The IKONIC-era troubleshooting manual documents a maintenance mode in which position *E shows the error codes of the most recent 8 faults, and the fault history can be verified as cleared (reading NULL at location 1E) after the reset procedure. Hybrids similarly hold current alarms behind the Next/Down display sequence. This memory is gold for intermittent faults: a heater that shows 12 today and nothing tomorrow has still told you it was losing flame, and a repeating cycle of 11-then-12 points at a supply that fails progressively rather than two unrelated faults. Before resetting anything, write down what is displayed, and scroll the history if your model offers it. Resetting first and reading later throws away the only evidence an intermittent fault leaves behind — which is why Rheem's own procedures put reading and recording ahead of clearing. A dated phone photograph of the display is the simplest fault log there is, and a series of them across a season is often what finally convinces a technician — or a warranty desk — that a fault is real, recurring, and patterned.
The most searched Rheem water heater codes, in detail
11 — Rheem tankless (RTGH / RTG / IKONIC): flame not detected by the flame rod. At ignition the unit tries to light twice, and if the flame rod never proves a flame, it shuts down and displays 11. The RTGH service chart gives the classic owner-level cause: the gas shut-off valve is not fully opened.
A Rheem tankless heater lights in a strict sequence. A hot tap opens, the flow sensor reports water moving, the blower runs a pre-purge to clear the combustion chamber, the gas valve opens in stages, and the igniter rod throws a visible spark at the burner — on these units you can watch for that spark through the sight glass. Lighting the gas is only half the job: a separate metal probe, the flame rod, sits in the flame and proves it is really burning by passing a tiny electrical current through the flame itself, a principle called flame rectification. Rheem's Tankless Troubleshooting Manual (AP21822) is precise about code 11: in the case of ignition failure, the water heater will attempt ignition 2 times, and if no flame is detected it displays 11 on the built-in controller or the remote controller. So an 11 means the sequence ran but proof of flame never arrived — either there was no spark, no gas to light, or a flame the rod could not sense. The manual's diagnostic check items for 11 are gas supply pressure, venting, the gas filter, the igniter rod, the flame rod, and the DIP switch settings. Correct supply pressure at the unit is 4.0 to 10.5 inches of water column for natural gas and 8.0 to 13.0 for LP, and Rheem stresses checking both static pressure (unit idle) and dynamic pressure (unit at maximum combustion), because pressure that looks fine at rest can sag when the burner and other appliances draw together. The simpler RTGH service chart in the Use and Care manual puts the most common real-world cause first: gas shut-off valve not fully opened — open it completely. Blocked or disconnected venting also causes 11, because the blower cannot establish the airflow the control expects before and during ignition. Code 11 is a lockout-style fault: the heater will not produce hot water until the cause is corrected, and repeated blind resets simply repeat two failed ignition attempts against a fault that has not changed. The same code appears in Rheem Australia's continuous-flow fault list as 'ignition failure at start up', which is why the diagnosis in this article follows the order all of Rheem's documents share: fuel first, air second, sensing third.
Most likely cause: Gas shut-off valve not fully open, or gas supply interrupted — Rheem's own RTGH service chart lists this first for code 11, and it is the most common cause in practice: a valve left half-open after plumbing work, a meter or supply interruption, or an LP tank that has run empty. The igniter can spark perfectly and the unit still shows 11, because there is simply nothing to light. Check that the valve handle at the heater is fully parallel to the pipe, confirm other gas appliances in the home work, and check the LP tank gauge if you heat with propane.
First check: Confirm other gas appliances in the home (stove, furnace) light and run normally — this separates a house supply problem from a heater problem.
If it keeps coming back: Code 11 returns when the underlying condition was never actually removed. A half-open valve gets nudged, works for a week, and drifts; a gas filter that caught debris once keeps catching it until the line is cleaned; an LP tank that 'still had a little in it' runs dry on the coldest night; a flame rod cleaned as a guess fouls again because the real problem was low dynamic pressure making a weak, poorly anchored flame. Treat a second 11 as data: note what else was running in the house and whether the vent terminations were clear, because that pattern is what the technician needs.
12 — Rheem tankless (RTGH / RTG / IKONIC): flame detected, then lost. The burner lit and the flame rod proved flame, but the flame dropped out during operation; Rheem's manual states the unit counts these flame-loss incidents and displays 12 after 3 consecutive losses. The RTGH service chart gives the plain-language causes: gas service interrupted, or LP gas running low.
Code 12 begins where code 11 ends. The ignition sequence succeeded — the flame rod proved a real flame — and the heater settled into heating. Then, mid-run, the flame signal vanished. Rheem's Tankless Troubleshooting Manual (AP21822) describes the behaviour exactly: if the water heater detects loss of flame during combustion, it stops supplying fuel, attempts to restart, and counts the incidents of flame loss; if the incident occurs 3 times consecutively, the unit displays 12 on the built-in controller or the remote. That counting matters for diagnosis: a single gust or a one-off pressure dip produces a restart you may never notice, while a 12 on the display means the flame is failing repeatedly and predictably. The causes sit in three groups. First, fuel delivery that degrades while running: LP gas running low (the RTGH chart names it directly), a gas service interruption, a gas filter at the heater's connection slowly strangling flow, or dynamic pressure sag when other appliances draw on the same line. Second, flame sensing that degrades: a flame rod coated in deposits may prove a strong flame at light-off yet drop the weaker or shifting signal mid-burn, and Rheem's diagnostic flow for 12 is built around cleaning and testing that rod. Third, combustion air: venting that is partly blocked or a termination exposed to gusts can disturb the flame until it lifts off the burner. The diagnostic check items Rheem lists for 12 are the same family as 11 — gas supply pressure (4.0-10.5 in. W.C. natural gas, 8.0-13.0 in. W.C. LP, checked dynamically), venting, gas filter, flame rod, and DIP switch settings — because the two codes share hardware and differ mainly in when the flame proof fails. A heater showing 12 usually still delivers some hot water in bursts between shutdowns, which is a useful symptom to report: cold bursts mid-shower with a 12 on the controller is the signature of flame loss under way, not a dead unit. Rheem Australia's chart compresses the same fault into four words — 'flame failure during operation' — and its owner-level remedies sit at the fuel end of the system, which matches field experience: most 12s are born in the supply or the sensing, not in the burner itself.
Most likely cause: LP gas running low, or gas service interrupted — Rheem's RTGH service chart reduces code 12 to two owner-level causes: gas service interrupted — contact the gas utility — or LP gas running low — refill or replace. A propane tank near empty delivers falling pressure exactly as demand rises, so the burner lights on what pressure exists and then starves. This is the first thing to check on any LP installation, and the cheapest: read the tank gauge before booking anyone. A tank showing a quarter or less in cold weather is effectively empty for a high-draw appliance, because the liquid vaporises more slowly as its temperature falls.
First check: If the home runs on LP/propane, read the tank gauge first — Rheem's own chart puts 'LP gas running low' at the top of this code's causes.
If it keeps coming back: Code 12 is a pattern code, so it comes back in patterns. Fill the LP tank and it vanishes until the tank runs low again. Clean the flame rod without fixing a pressure sag and it returns on the first cold morning the furnace runs hard. Clear a vent termination and it returns when the nest is rebuilt. The count-to-three behaviour also means the fault can simmer invisibly — single flame losses, silently restarted — before it ever displays. If your household notices unexplained cold bursts in the shower, treat that as early 12 behaviour and get the supply and rod checked before the lockouts start.
29 — Rheem tankless, and the meaning depends on generation. On condensing IKONIC-era models: condensation is not draining from the collector
A condensing tankless heater squeezes extra heat from its exhaust, and the price of that efficiency is water: vapour in the flue gas condenses inside the secondary heat exchanger and must drain away continuously while the burner runs. Rheem's current condensing design collects that condensate in a built-in drain trap, and the trap is supervised — Rheem's Tankless Troubleshooting Manual (AP21822) explains that if the electrode on the drain trap detects the water level is full, or cannot detect the water level in the trap, the heater displays 29 on the built-in or remote controller and stops. It is a protective stop: a trap that cannot drain will eventually back condensate into places it can damage, and acidic condensate is not something the heater will let pool inside itself. The manual's diagnostic items are short and physical: the drain connection on the trap, and the drain line. Two installation leftovers cause a large share of 29s on newer units — the protection plug on the drain connection at the bottom of the unit was never removed, so condensate has nowhere to go from day one; and the drain line has been fitted with a P-trap, which Rheem explicitly says the line does not need and instructs to remove, because the unit already contains a trap. A pinched or blocked drain line, or a frozen line in an unheated space, produces the same code on older installations. On the previous RTGH condensing generation the chart expresses the same physics from the neutralizer's side: 29 means the neutralizer — the canister of media that treats the acidic condensate — is clogged, and its companions 92 (neutralizer replacement due soon, unit usable) and 93 (neutralizer must be replaced, unit unusable) chart the media's end of life. Only on the older non-condensing RTG generation and in Rheem Australia's chart does 29 carry a different meaning entirely — heat exchanger outlet temperature too low, fixed by cleaning the air inlet screen and heat exchanger fins. Same number, three adjacent stories, all documented by Rheem: the constant thread is that 29 is about the condensate path on any condensing model.
Most likely cause: Protection plug left in the drain connection — Rheem's manual flags this in a formal notice: the protection plug on the drain connection may not have been removed, and it must be taken out of the connection at the bottom of the unit. Shipping plugs exist to keep debris out during installation; if the installer missed it, the trap has been sealed since day one and the first real condensate load fills it. This is the prime suspect on any unit that shows 29 in its first season, and the fix is literally pulling a plug — though access and confirmation are often easiest for the installer to close out.
First check: Start at the bottom of the unit: find the condensate drain connection and confirm the protection plug was removed and the line is actually attached.
If it keeps coming back: Condensate problems recur on a schedule set by physics. A line cleared of sludge grows it again in a year or two, especially on a slow, flat run. Neutralizer media dissolves by design, so 92, then 29 or 93, return when the new charge is spent. A plug or P-trap problem, once fixed, stays fixed — but a frozen line freezes every hard winter until it is insulated or re-routed, which is why winter-only 29s should be believed rather than reset. And a trap electrode that has posted one false 'full' report through scale fouling will do it again until it is cleaned or replaced.
E5 — Rheem electric tankless (EcoSmart / RTEX platform): high flow rate. The water is moving through the heater faster than its elements can bring it to the set temperature, so the outlet runs lukewarm and the control reports E5. EcoSmart's troubleshooting guide
An electric tankless heater has no stored hot water. Every degree of temperature rise must be added in the seconds water spends inside the heat exchanger, and the elements can only add a fixed amount of energy per second. That physics defines a hard ceiling: at a given incoming water temperature and set point, there is a maximum flow the unit can serve at temperature. Push more water through than that ceiling — a rain shower plus a filled tub, two bathrooms at once, a high-flow fixture with no restrictor — and the same element power is spread across more water, so outlet temperature sags and the control posts E5, which the EcoSmart troubleshooting guide defines as high flow rate. Notice what E5 is not: it is not an overheat (that is E4 on this platform, where outlet temperature runs too high), not a sensor failure (E1 inlet thermistor, E2 outlet thermistor, E3 both), and not an ignition or flame fault — an electric unit has no flame, so the 'E5 means ignition failure' claims circulating on generic code lists are describing some other appliance entirely. E5 behaves like a live measurement rather than a latched fault: throttle the flow back into the unit's range and full temperature returns, which is also the diagnostic test. Anything that lowers the ceiling produces the same code at ordinary flows — winter groundwater demanding a much larger temperature rise, one of the unit's several breaker circuits switched off or tripped so only part of the element bank is powered, or heavy scale narrowing the exchanger. The documented owner responses all work on the flow side of the equation: reduce flow at the fixtures, fit aerators or flow restrictors, and as a test, partially close the inlet valve slightly to see whether full temperature returns at reduced flow — if it does, the heater is healthy and the household demand is simply bigger than the unit. That last point is the honest endpoint of many E5 investigations: the code is the heater accurately reporting that it is undersized for how the home now uses hot water.
Most likely cause: Too many fixtures drawing at once — The classic E5: a shower running while a tub fills, the washing machine's hot fill, and a kitchen tap together exceed what the elements can serve. Each fixture alone is fine; the sum is not. Because the code tracks live flow, it appears at peak moments — mornings, laundry day — and vanishes when demand drops. No part is failing; the household has simply found the heater's ceiling. Staggering draws or trimming fixture flow rates resolves it.
First check: Run one low-flow hot tap alone (a single bathroom faucet with an aerator): if the water reaches full set temperature and E5 stays away, the heater works and the issue is total flow.
If it keeps coming back: E5 returns whenever the balance tips again: a new high-flow showerhead fitted during a bathroom refresh, guests in the house doubling morning demand, a breaker switched off during unrelated panel work and never restored, or the first cold snap dropping inlet temperatures and cutting the unit's effective capacity. Scale building inside the exchanger slowly lowers the ceiling too, so an E5 threshold that creeps downward over years is worth a service visit and a flush. The code is best read as a gauge, not an alarm — when it reappears, ask what changed: demand, power, season, or the unit.
Less common and model-specific codes
Search data shows owners also meet these codes on Rheem water heaters: Heater. They are not part of the core code list Rheem publishes for most models — several are series-specific, abbreviated display readings, or codes carried over from a sister platform — so we do not publish meanings for them rather than guess. Treat them by symptom: note what the machine was doing when the code appeared (filling, draining, heating, spinning), run one full power cycle (5 minutes off), and if the code returns, match the symptom to the closest documented family in the table above and check the tech sheet stored inside your machine for the model-specific definition.
Deep-dive guides for the most searched codes
Related guides
Facts on this page were checked against manufacturer documentation: files.myrheem.com · files.myrheem.com · www.manualshelf.com · www.manualshelf.com · www.manualshelf.com · mans.io · manuals.plus · manuals.plus · manuals.plus