Rheem Furnace Error Codes List: Every Code ExplainedRheem Furnace 11 Error Code: Meaning, Causes & FixRheem Furnace Flame Error Codes (12, 13, 14): Meaning & FixesRheem Furnace Limit & Rollout Codes (22, 33): Meaning & FixesRheem Furnace Pressure Switch Codes (55, 57): Meaning & FixesRheem Furnace 61 Error Code: Meaning, Causes & FixHow to Reset Rheem Furnace Error CodesRheem Furnace Blinking Light Codes: Legacy LED Flashes Explained

Most searched Rheem furnace codes

CodeMeaning
11Failed ignition — the furnace control ran an ignition attempt and flame was not established and proved; the code is displayed after the first failed attempt and stays until ignition succeeds or the failures escalate to lockout.
61Blower fault — blower unable to run. Critical: no operation in any mode. Rheem also declares 61 when the main limit has been open over 150 seconds during a heat call (the display then alternates 61 and 22): the control reads a limit that cannot re-close as a dead blower, because the blower should be carrying the heat away. A fourth dead-blower declaration in one heat call enters hard lockout.