FixCode Guide
Home › Lennox › Lennox Furnace › Lennox Furnace Error Codes List: Every Code Explained

Lennox Furnace Error Codes List: Every Code Explained

Lennox Furnace display showing full error code list — FixCode Guide error code graphic

Every Lennox furnace error code we could verify against Lennox's own documentation — what it means, what usually causes it, and the first fix to try — in one table. Codes differ between model series, so treat your model's tech sheet as the final word.

Safety first. Work safe: power off at the plug or breaker before panels come off, taps closed before hoses come off, and no bypassing of safety devices — ever. Never bypass safety limits or pressure/flame devices. Gas smell, scorch marks or a CO alarm = stop and call a licensed HVAC technician.

How to read and retrieve error codes on Lennox furnaces

Lennox boards store a fault history readable through the board display and, on iComfort systems, through the thermostat's alert history — the most reliable way to see intermittent faults that never appear while a technician is watching.

The complete Lennox furnace error code list

CodeMeaningMost likely causeFirst fix
E105Device communication problem; no other devices found on the RSBus communication systemLoose or damaged communicating wiring, unresponsive thermostat, or electrical noise on the busPower-cycle the system once and check thermostat wiring; persistent faults need a licensed HVAC technician
E110Low AC line voltage detected by the controlLow household supply voltage, overloaded circuit, or poor electrical connectionCheck the breaker is fully on; persistent low voltage needs a licensed HVAC technician or electrician
E125Control hardware failure, including A/D electronics and flame test circuitry (five-minute lockout)Failed integrated control board hardwareTry one power reset after five minutes; board replacement is licensed HVAC technician work
E131Corrupted control parameters; non-volatile data corruption (communicating mode)Control board memory or configuration faultSystem reconfiguration or control replacement is licensed HVAC technician work
E150A2L refrigerant leak detected; thermostat lockout while mitigation runsRefrigerant leak sensed by the leak detector, or detector faultDo not bypass the mitigation system; refrigerant leaks need a licensed HVAC technician
E154Refrigerant leak detector sensor 1 communication lostDisconnected or failed leak detector sensor, or damaged sensor wiringSensor and wiring diagnosis is licensed HVAC technician work; do not disable the detector
E155Refrigerant leak detector sensor 2 communication lostDisconnected or failed leak detector sensor, or damaged sensor wiringSensor and wiring diagnosis is licensed HVAC technician work; do not disable the detector
E180Outdoor air temperature sensor failureFailed outdoor sensor, or loose or damaged sensor wiringCheck the outdoor sensor connection; sensor replacement is licensed HVAC technician work
E200Hard lockout: rollout switch open, or previously openedFlame rollout from blocked venting, dirty burners, or heat exchanger problemsTurn the furnace off and do not reset the rollout; call a licensed HVAC technician
E201Communication fault on Lennox communicating (iComfort) furnaces — the system components have lost communication (E201 is the iComfort comms-loss alert).Communicating wiring faultRestore power to the silent component (clear the condensate trap if the float tripped — find why it filled).
E205Soft lockout: gas valve relay (first or second stage) contact shortedShorted gas valve relay contact on the control, or valve wiring faultDo not keep resetting; gas valve and control work needs a licensed HVAC technician
E207Hot surface ignitor sensed openCracked or burned-out ignitor, or open ignitor wiringIgnitor replacement is licensed HVAC technician work; handle the new ignitor by its base only
E223Low pressure switch failed to close (stuck open) on a call for heatBlocked vent or intake, clogged condensate, damaged switch hose, weak inducerClear vent and intake terminations and check the condensate drain; then a licensed HVAC technician
E224Low pressure switch failed to open (stuck closed)Sticking switch contacts, or water or debris holding the switch closedCheck vent terminations are clear; switch testing is licensed HVAC technician work
E225High pressure switch failed to close (stuck open)Vent or intake restriction, condensate backup, hose fault, or weak inducerClear vent and intake terminations and check the condensate drain; then a licensed HVAC technician
E226High pressure switch failed to open (stuck closed)Sticking switch contacts, or shorted switch wiringSwitch and draft testing with a manometer is licensed HVAC technician work
E227Low pressure switch opened during trial for ignition or run modeVent or intake restriction, condensate backup, cracked hose, or weakening inducerClear vent and intake terminations and check the condensate drain; persistent faults need a licensed HVAC technician
E228Unable to perform a successful pressure switch calibrationVent system restriction, or pressure switch wiring connection faultClear vent terminations; control retries after 300 seconds, otherwise a licensed HVAC technician
E229Ignition occurred on high fire instead of the expected low fire stagePressure switch or staging fault causing high-fire ignitionNote the code for the technician; staging diagnosis is licensed HVAC technician work
E240Low flame current in run mode; the flame signal is too weakCoated flame sensor, poor unit ground, or weak burner flameFlame sensor cleaning and ground checks are licensed HVAC technician work
E241Flame sensed out of sequence; flame still present when it should be goneLeaking gas valve keeping a burner flame aliveShut off gas to the furnace and call a licensed HVAC technician immediately
E250Primary limit switch circuit open; the furnace overheatedLow airflow from clogged filter or blocked ducts, or overfired burnersReplace the filter and open registers and returns; repeat trips need a licensed HVAC technician
E270Soft lockout: maximum ignition retries exceeded, no flame current sensedNo gas flow, ignitor not lighting burners, or dead flame sensorConfirm gas supply to the home is on; ignition diagnosis is licensed HVAC technician work
E271Soft lockout: maximum retries exceeded; last retry failed from pressure switch openingVent restriction, condensate backup, or pressure switch fault dropping draft proofClear vent and intake terminations and check the condensate drain; then a licensed HVAC technician
E272Soft lockout: maximum recycles exceeded; last recycle from pressure switch openingMarginal draft from vent restriction, condensate, hose fault, or weak inducerClear vent and intake terminations and check the condensate drain; persistent lockout needs a licensed HVAC technician
E273Soft lockout: maximum recycles exceeded; last recycle from flame failure in run modeFlame loss from gas pressure problems, dirty sensor, or burner issuesGas pressure and burner diagnosis is licensed HVAC technician work
E274Soft lockout: limit switch open for more than three minutesSevere airflow restriction overheating the furnace, or failing blowerReplace the filter and open all registers and returns; if it repeats, call a licensed HVAC technician
E275Soft lockout: flame detected out of sequence, and the flame is now goneEarlier out-of-sequence flame, possibly a leaking gas valve or sensor faultGas valve leak checks are licensed HVAC technician work; do not ignore this code
E290Ignitor circuit fault; failed ignitor or its triggering circuitryOpen or shorted ignitor, or failed control ignitor outputIgnitor and control diagnosis is licensed HVAC technician work
E292Indoor blower unable to startObstructed blower wheel, seized motor bearings, or failed motor moduleTurn power off and replace a collapsed filter; motor work is licensed HVAC technician work
E295Indoor blower motor temperature too highRestricted airflow, dirty blower wheel, or failing motor bearingsReplace the filter and open registers and returns; motor checks need a licensed HVAC technician
E310Discharge air sensor failure; sensor shorted or reading out of rangeFailed discharge air temperature sensor or damaged sensor wiringSensor replacement is licensed HVAC technician work
E311Restricted airflow in heating; firing rate reduced to match available airflowClogged filter, blocked returns, or restrictive ductwork limiting blower airflowReplace the filter and open all registers and returns; duct static checks need a licensed HVAC technician
E312Restricted airflow in cooling or continuous fan mode; warning only, blower in cutbackClogged filter, blocked returns, or restrictive ductwork limiting blower airflowReplace the filter and open all registers and returns; warning clears when airflow recovers
A code that is not in this table? Manufacturers add and retire codes between model years, and some displays abbreviate two-part codes. If your code is missing, note the full display exactly as shown (photograph it), check the tech sheet stored inside the machine, and search this site by the symptom — the fault family is usually identifiable from what the machine was doing when the code appeared.

How to reset / clear error codes on Lennox furnaces

Lennox furnaces show alphanumeric codes on the board's 7-segment display (and on iComfort thermostats). Most codes clear when the fault condition ends and a successful cycle completes; communication codes (the E2xx family) clear with a power cycle of both the indoor unit and the thermostat once wiring is checked. A recurring code after reset is an active fault.

How to diagnose any Lennox furnace code

Work the problem in this order — and stop at any point where gas, combustion or mains wiring is involved, because those belong to a licensed HVAC technician: (1) record the code exactly: count LED flashes slowly, twice, or photograph the alphanumeric display; (2) check the free things homeowners legitimately own: the thermostat is calling for heat, the furnace power switch and breaker are on, the filter is not clogged solid (a starved furnace overheats and locks out on limit codes), all vents and the return are open, and the condensate drain is not blocked on condensing models; (3) reset once — at the power switch, off for 30 seconds — then watch a full call for heat from the beginning: inducer, ignition, flame, blower, in that order; where the sequence stops is the fault family the code names; (4) a code that returns immediately is an active fault — do not keep resetting a lockout, especially any flame or limit code; (5) everything inside the burner compartment — flame sensor cleaning is the one grey area many manuals allow owners, but gas valves, burners, heat exchangers and control boards are professional work. If you smell gas at any point, leave and call the gas utility, not a helpline.

How Lennox reports faults

Lennox has used two reporting generations. Older boards flash a single LED in patterns counted against the chart inside the blower door. Newer integrated controls show alphanumeric E-codes on a small display and store a history of recent faults that a technician can recall — useful, because an intermittent fault (a pressure switch that fails only on windy days, a flame signal that fades as the sensor oxidises) often appears in the history even when the current call for heat succeeds. The table below covers the E-code generation; for a flashing-LED board, your door chart is the authority for your exact model.

Codes that share a system

Lennox E-codes cluster by the step of the heating sequence they monitor: inducer and pressure-switch codes, ignition and flame codes, limit and rollout codes, blower codes, and communication codes between the thermostat and the control. When two codes appear together, read them as one story — a limit code after a blower code usually means the blower fault overheated the furnace, not that two parts failed at once.

Reading the chart inside the door

On flashing-LED models the chart is glued inside the blower compartment door, and it — not any website — is the authority for your furnace, because Lennox reused flash counts across product generations. Count carefully: the pattern repeats with a longer pause between repeats, flashes within a pattern may mix long and short, and a steady-on or steady-off LED is itself a status (normal operation or no power / board fault, per the chart). Write the count down before resetting anything; a lockout cleared at the switch takes its evidence with it.

Blink codes, display codes and lockouts

Two generations of fault reporting live side by side on modern furnaces. Older and simpler boards report through a single LED: a repeating count of flashes, read slowly against the chart printed inside the blower door — that chart, for your exact model, outranks any list on the internet, including this one. Newer communicating furnaces show alphanumeric codes (the E-series in the table above) and store a fault history a technician can scroll. Both generations share the lockout idea: after a set number of failed attempts at the same step — ignition is the classic — the board stops trying for a period (often an hour, or until power is cycled) instead of cycling forever against a fault that could overheat or flood the burners with unburned gas. A furnace in lockout is not broken by the lockout itself; it is a furnace that has already failed the same step repeatedly and is waiting for someone to find out why.

Furnace codes are also seasonal in a way washer codes are not. The first cold snap produces a wave of ignition and flame codes from furnaces that sat idle all summer — oxidised flame sensors, spider-nested burners, pressure-switch hoses holding condensate from the cooling season. Deep-winter adds frozen condensate lines on high-efficiency models and intake/exhaust terminations blocked by snow or ice, which present as pressure-switch codes. A code that appears once, on the coldest night of the year, and never again has often met its cause already; a code that appears every cycle, in any weather, is a component asking to be tested.

The most searched Lennox furnace codes, in detail

E201 — Communication fault on Lennox communicating (iComfort) furnaces

Lennox's communicating systems (iComfort thermostats with matching furnaces/air handlers) report E201 when the equipment stops communicating on the system's bus — the thermostat can't talk to the indoor unit (or a component has dropped off the bus). Causes are wiring (the 4-wire communicating run), a component without power, or a board fault. Non-communicating Lennox furnaces use LED codes instead, so E201 also tells you which Lennox generation you own.

Most likely cause: Communicating wiring fault — A loose, corroded or damaged conductor in the thermostat-to-unit bus run.

First check: Check the obvious power items first: furnace switch on, breaker on, and the condensate overflow float switch (a tripped float kills the unit's power and looks like a comms fault).

If it keeps coming back: E201 returning with condensate refills points at a slow drain — the comms code is downstream of a drain problem.

Less common and model-specific codes

Search data shows owners also meet these codes on Lennox furnaces: 227, 228, 240, 270, 292, C2, Fixes, Furnace, H1, H2. They are not part of the core code list Lennox publishes for most models — several are series-specific, abbreviated display readings, or codes carried over from a sister platform — so we do not publish meanings for them rather than guess. Treat them by symptom: note what the machine was doing when the code appeared (filling, draining, heating, spinning), run one full power cycle (5 minutes off), and if the code returns, match the symptom to the closest documented family in the table above and check the tech sheet stored inside your machine for the model-specific definition.