Lennox Furnace Error Codes List: Every Code Explained
Every Lennox furnace error code we could verify against Lennox's own documentation — what it means, what usually causes it, and the first fix to try — in one table. Codes differ between model series, so treat your model's tech sheet as the final word.
How to read and retrieve error codes on Lennox furnaces
Lennox boards store a fault history readable through the board display and, on iComfort systems, through the thermostat's alert history — the most reliable way to see intermittent faults that never appear while a technician is watching.
The complete Lennox furnace error code list
| Code | Meaning | Most likely cause | First fix |
|---|---|---|---|
| E105 | Device communication problem; no other devices found on the RSBus communication system | Loose or damaged communicating wiring, unresponsive thermostat, or electrical noise on the bus | Power-cycle the system once and check thermostat wiring; persistent faults need a licensed HVAC technician |
| E110 | Low AC line voltage detected by the control | Low household supply voltage, overloaded circuit, or poor electrical connection | Check the breaker is fully on; persistent low voltage needs a licensed HVAC technician or electrician |
| E125 | Control hardware failure, including A/D electronics and flame test circuitry (five-minute lockout) | Failed integrated control board hardware | Try one power reset after five minutes; board replacement is licensed HVAC technician work |
| E131 | Corrupted control parameters; non-volatile data corruption (communicating mode) | Control board memory or configuration fault | System reconfiguration or control replacement is licensed HVAC technician work |
| E150 | A2L refrigerant leak detected; thermostat lockout while mitigation runs | Refrigerant leak sensed by the leak detector, or detector fault | Do not bypass the mitigation system; refrigerant leaks need a licensed HVAC technician |
| E154 | Refrigerant leak detector sensor 1 communication lost | Disconnected or failed leak detector sensor, or damaged sensor wiring | Sensor and wiring diagnosis is licensed HVAC technician work; do not disable the detector |
| E155 | Refrigerant leak detector sensor 2 communication lost | Disconnected or failed leak detector sensor, or damaged sensor wiring | Sensor and wiring diagnosis is licensed HVAC technician work; do not disable the detector |
| E180 | Outdoor air temperature sensor failure | Failed outdoor sensor, or loose or damaged sensor wiring | Check the outdoor sensor connection; sensor replacement is licensed HVAC technician work |
| E200 | Hard lockout: rollout switch open, or previously opened | Flame rollout from blocked venting, dirty burners, or heat exchanger problems | Turn the furnace off and do not reset the rollout; call a licensed HVAC technician |
| E201 | Communication fault on Lennox communicating (iComfort) furnaces — the system components have lost communication (E201 is the iComfort comms-loss alert). | Communicating wiring fault | Restore power to the silent component (clear the condensate trap if the float tripped — find why it filled). |
| E205 | Soft lockout: gas valve relay (first or second stage) contact shorted | Shorted gas valve relay contact on the control, or valve wiring fault | Do not keep resetting; gas valve and control work needs a licensed HVAC technician |
| E207 | Hot surface ignitor sensed open | Cracked or burned-out ignitor, or open ignitor wiring | Ignitor replacement is licensed HVAC technician work; handle the new ignitor by its base only |
| E223 | Low pressure switch failed to close (stuck open) on a call for heat | Blocked vent or intake, clogged condensate, damaged switch hose, weak inducer | Clear vent and intake terminations and check the condensate drain; then a licensed HVAC technician |
| E224 | Low pressure switch failed to open (stuck closed) | Sticking switch contacts, or water or debris holding the switch closed | Check vent terminations are clear; switch testing is licensed HVAC technician work |
| E225 | High pressure switch failed to close (stuck open) | Vent or intake restriction, condensate backup, hose fault, or weak inducer | Clear vent and intake terminations and check the condensate drain; then a licensed HVAC technician |
| E226 | High pressure switch failed to open (stuck closed) | Sticking switch contacts, or shorted switch wiring | Switch and draft testing with a manometer is licensed HVAC technician work |
| E227 | Low pressure switch opened during trial for ignition or run mode | Vent or intake restriction, condensate backup, cracked hose, or weakening inducer | Clear vent and intake terminations and check the condensate drain; persistent faults need a licensed HVAC technician |
| E228 | Unable to perform a successful pressure switch calibration | Vent system restriction, or pressure switch wiring connection fault | Clear vent terminations; control retries after 300 seconds, otherwise a licensed HVAC technician |
| E229 | Ignition occurred on high fire instead of the expected low fire stage | Pressure switch or staging fault causing high-fire ignition | Note the code for the technician; staging diagnosis is licensed HVAC technician work |
| E240 | Low flame current in run mode; the flame signal is too weak | Coated flame sensor, poor unit ground, or weak burner flame | Flame sensor cleaning and ground checks are licensed HVAC technician work |
| E241 | Flame sensed out of sequence; flame still present when it should be gone | Leaking gas valve keeping a burner flame alive | Shut off gas to the furnace and call a licensed HVAC technician immediately |
| E250 | Primary limit switch circuit open; the furnace overheated | Low airflow from clogged filter or blocked ducts, or overfired burners | Replace the filter and open registers and returns; repeat trips need a licensed HVAC technician |
| E270 | Soft lockout: maximum ignition retries exceeded, no flame current sensed | No gas flow, ignitor not lighting burners, or dead flame sensor | Confirm gas supply to the home is on; ignition diagnosis is licensed HVAC technician work |
| E271 | Soft lockout: maximum retries exceeded; last retry failed from pressure switch opening | Vent restriction, condensate backup, or pressure switch fault dropping draft proof | Clear vent and intake terminations and check the condensate drain; then a licensed HVAC technician |
| E272 | Soft lockout: maximum recycles exceeded; last recycle from pressure switch opening | Marginal draft from vent restriction, condensate, hose fault, or weak inducer | Clear vent and intake terminations and check the condensate drain; persistent lockout needs a licensed HVAC technician |
| E273 | Soft lockout: maximum recycles exceeded; last recycle from flame failure in run mode | Flame loss from gas pressure problems, dirty sensor, or burner issues | Gas pressure and burner diagnosis is licensed HVAC technician work |
| E274 | Soft lockout: limit switch open for more than three minutes | Severe airflow restriction overheating the furnace, or failing blower | Replace the filter and open all registers and returns; if it repeats, call a licensed HVAC technician |
| E275 | Soft lockout: flame detected out of sequence, and the flame is now gone | Earlier out-of-sequence flame, possibly a leaking gas valve or sensor fault | Gas valve leak checks are licensed HVAC technician work; do not ignore this code |
| E290 | Ignitor circuit fault; failed ignitor or its triggering circuitry | Open or shorted ignitor, or failed control ignitor output | Ignitor and control diagnosis is licensed HVAC technician work |
| E292 | Indoor blower unable to start | Obstructed blower wheel, seized motor bearings, or failed motor module | Turn power off and replace a collapsed filter; motor work is licensed HVAC technician work |
| E295 | Indoor blower motor temperature too high | Restricted airflow, dirty blower wheel, or failing motor bearings | Replace the filter and open registers and returns; motor checks need a licensed HVAC technician |
| E310 | Discharge air sensor failure; sensor shorted or reading out of range | Failed discharge air temperature sensor or damaged sensor wiring | Sensor replacement is licensed HVAC technician work |
| E311 | Restricted airflow in heating; firing rate reduced to match available airflow | Clogged filter, blocked returns, or restrictive ductwork limiting blower airflow | Replace the filter and open all registers and returns; duct static checks need a licensed HVAC technician |
| E312 | Restricted airflow in cooling or continuous fan mode; warning only, blower in cutback | Clogged filter, blocked returns, or restrictive ductwork limiting blower airflow | Replace the filter and open all registers and returns; warning clears when airflow recovers |
How to reset / clear error codes on Lennox furnaces
Lennox furnaces show alphanumeric codes on the board's 7-segment display (and on iComfort thermostats). Most codes clear when the fault condition ends and a successful cycle completes; communication codes (the E2xx family) clear with a power cycle of both the indoor unit and the thermostat once wiring is checked. A recurring code after reset is an active fault.
How to diagnose any Lennox furnace code
Work the problem in this order — and stop at any point where gas, combustion or mains wiring is involved, because those belong to a licensed HVAC technician: (1) record the code exactly: count LED flashes slowly, twice, or photograph the alphanumeric display; (2) check the free things homeowners legitimately own: the thermostat is calling for heat, the furnace power switch and breaker are on, the filter is not clogged solid (a starved furnace overheats and locks out on limit codes), all vents and the return are open, and the condensate drain is not blocked on condensing models; (3) reset once — at the power switch, off for 30 seconds — then watch a full call for heat from the beginning: inducer, ignition, flame, blower, in that order; where the sequence stops is the fault family the code names; (4) a code that returns immediately is an active fault — do not keep resetting a lockout, especially any flame or limit code; (5) everything inside the burner compartment — flame sensor cleaning is the one grey area many manuals allow owners, but gas valves, burners, heat exchangers and control boards are professional work. If you smell gas at any point, leave and call the gas utility, not a helpline.
How Lennox reports faults
Lennox has used two reporting generations. Older boards flash a single LED in patterns counted against the chart inside the blower door. Newer integrated controls show alphanumeric E-codes on a small display and store a history of recent faults that a technician can recall — useful, because an intermittent fault (a pressure switch that fails only on windy days, a flame signal that fades as the sensor oxidises) often appears in the history even when the current call for heat succeeds. The table below covers the E-code generation; for a flashing-LED board, your door chart is the authority for your exact model.
Codes that share a system
Lennox E-codes cluster by the step of the heating sequence they monitor: inducer and pressure-switch codes, ignition and flame codes, limit and rollout codes, blower codes, and communication codes between the thermostat and the control. When two codes appear together, read them as one story — a limit code after a blower code usually means the blower fault overheated the furnace, not that two parts failed at once.
Reading the chart inside the door
On flashing-LED models the chart is glued inside the blower compartment door, and it — not any website — is the authority for your furnace, because Lennox reused flash counts across product generations. Count carefully: the pattern repeats with a longer pause between repeats, flashes within a pattern may mix long and short, and a steady-on or steady-off LED is itself a status (normal operation or no power / board fault, per the chart). Write the count down before resetting anything; a lockout cleared at the switch takes its evidence with it.
Blink codes, display codes and lockouts
Two generations of fault reporting live side by side on modern furnaces. Older and simpler boards report through a single LED: a repeating count of flashes, read slowly against the chart printed inside the blower door — that chart, for your exact model, outranks any list on the internet, including this one. Newer communicating furnaces show alphanumeric codes (the E-series in the table above) and store a fault history a technician can scroll. Both generations share the lockout idea: after a set number of failed attempts at the same step — ignition is the classic — the board stops trying for a period (often an hour, or until power is cycled) instead of cycling forever against a fault that could overheat or flood the burners with unburned gas. A furnace in lockout is not broken by the lockout itself; it is a furnace that has already failed the same step repeatedly and is waiting for someone to find out why.
Furnace codes are also seasonal in a way washer codes are not. The first cold snap produces a wave of ignition and flame codes from furnaces that sat idle all summer — oxidised flame sensors, spider-nested burners, pressure-switch hoses holding condensate from the cooling season. Deep-winter adds frozen condensate lines on high-efficiency models and intake/exhaust terminations blocked by snow or ice, which present as pressure-switch codes. A code that appears once, on the coldest night of the year, and never again has often met its cause already; a code that appears every cycle, in any weather, is a component asking to be tested.
The most searched Lennox furnace codes, in detail
E201 — Communication fault on Lennox communicating (iComfort) furnaces
Lennox's communicating systems (iComfort thermostats with matching furnaces/air handlers) report E201 when the equipment stops communicating on the system's bus — the thermostat can't talk to the indoor unit (or a component has dropped off the bus). Causes are wiring (the 4-wire communicating run), a component without power, or a board fault. Non-communicating Lennox furnaces use LED codes instead, so E201 also tells you which Lennox generation you own.
Most likely cause: Communicating wiring fault — A loose, corroded or damaged conductor in the thermostat-to-unit bus run.
First check: Check the obvious power items first: furnace switch on, breaker on, and the condensate overflow float switch (a tripped float kills the unit's power and looks like a comms fault).
If it keeps coming back: E201 returning with condensate refills points at a slow drain — the comms code is downstream of a drain problem.
Less common and model-specific codes
Search data shows owners also meet these codes on Lennox furnaces: 227, 228, 240, 270, 292, C2, Fixes, Furnace, H1, H2. They are not part of the core code list Lennox publishes for most models — several are series-specific, abbreviated display readings, or codes carried over from a sister platform — so we do not publish meanings for them rather than guess. Treat them by symptom: note what the machine was doing when the code appeared (filling, draining, heating, spinning), run one full power cycle (5 minutes off), and if the code returns, match the symptom to the closest documented family in the table above and check the tech sheet stored inside your machine for the model-specific definition.