Goodman Furnace Error Codes List: Every Code Explained

Goodman Furnace display showing full error code list — FixCode Guide error code graphic

Every Goodman furnace error code we could verify against Goodman's own documentation — what it means, what usually causes it, and the first fix to try — in one table. Codes differ between model series, so treat your model's tech sheet as the final word.

Safety first. Safety first: disconnect power before any internal check, and never defeat a safety switch or sensor to 'test' an appliance. Never bypass safety limits or pressure/flame devices. Gas smell, scorch marks or a CO alarm = stop and call a licensed HVAC technician.

How to read and retrieve error codes on Goodman furnaces

Goodman boards keep the last faults readable via the display/LED, and newer models expose fault history through the CoolCloudHVAC app and the onboard menu. The fault chart on the blower door remains the authority — Goodman reused similar-looking codes across board generations.

The complete Goodman furnace error code list

CodeMeaningMost likely causeFirst fix
1 FLASHSystem lockout after excessive ignition retries; two-stage boards: flame sensed with no flame presentFailed ignition attempts, or gas valve stuck open or shorted flame sensor wiringCheck thermostat call and gas supply on; do not keep resetting, call a licensed HVAC technician
2 FLASHPressure switch stuck closed before the inducer startsSticking pressure switch contacts, shorted switch wiring, or stuck inducer relayCheck vent terminations are clear; switch or board diagnosis needs a licensed HVAC technician
3 DOUBLE FLASHESSecond-stage pressure switch stuck open during high-stage inducer operationBlocked or pinched switch hose, vent restriction, or weak high-stage inducer draftClear vent and intake terminations; switch and draft testing by a licensed HVAC technician
3 FLASHPressure switch failed to close (stuck open) when the inducer ranBlocked vent or intake, clogged condensate drain, cracked switch hose, weak inducerClear vent and intake terminations and check condensate drain; further diagnosis by a licensed HVAC technician
4 FLASHOpen high limit circuit; the furnace overheated and shut the burners downClogged filter, blocked registers or returns, failing blower, excessive temperature riseReplace the filter and open all registers and returns; repeat trips need a licensed HVAC technician
5 FLASHFlame sensed without the gas valve energized; two-stage boards: open rollout or blown fuseLeaking gas valve, lingering flame, open rollout switch, or open control board fuseTurn the furnace off; gas valve, rollout and fuse faults need a licensed HVAC technician
6 FLASHSingle-stage boards: open rollout switch; two-stage boards: pressure switch cycling lockoutRollout from blocked flue or cracked heat exchanger, or pressure switch opening repeatedlyTurn the furnace off and do not reset repeatedly; call a licensed HVAC technician
7 FLASHSingle-stage boards: low flame sense signal; two-stage boards: lockout after excessive ignition retriesCoated flame sensor, weak gas pressure, or flame never proven during ignition trialsCheck gas supply to the home is on; sensor and gas work needs a licensed HVAC technician
8 FLASHLockout after excessive recycles; flame was proven, then lost repeatedlyInterrupted gas supply, low gas pressure, opening pressure switch, or failing flame sensorDo not keep power-cycling; gas pressure and burner diagnosis need a licensed HVAC technician
9 FLASHImproper grounding or reversed 115-volt polarity at the furnaceHot and neutral supply wires reversed, or missing equipment groundDo not operate; correct wiring polarity and grounding via a licensed HVAC technician or electrician
9HNot a standard published Goodman furnace fault — treat as a platform/display-specific reading to be decoded with the model number (Goodman's systems are LED blink codes and E-codes on communicating models).Display/thermostat rendering from a communicating systemFollow the decoded fault's family playbook (ignition/limit/pressure as applicable).
10 FLASHGas valve energized or gas flowing with no call for heatShorted gas valve wiring, or control board output fault energizing the valveShut off gas and power to the furnace; call a licensed HVAC technician immediately
11 FLASHLimit switch circuit open over five minutes, suggesting blower failureFailed circulator blower, or limit circuit still open after overheatingReplace the filter and check the blower runs; blower repair needs a licensed HVAC technician
12 FLASHControl board igniter relay is not energizing the igniterFailed igniter relay on the integrated control boardControl board replacement is required; call a licensed HVAC technician
A2LR-32 models: A2L refrigerant alarm active (leak, communication, internal, or relay alarm)Refrigerant leak detected by the mitigation sensor, or sensor communication failureDo not ignore or bypass the alarm; refrigerant leak work needs a licensed HVAC technician
CONTINUOUS OFFLED off: no power reaching the control, or control failureTripped breaker, open door or disconnect switch, blown board fuse, no 24V powerCheck breaker, furnace switch and door seating; fuse or board work needs a licensed HVAC technician
CONTINUOUS ONSteady LED: normal standby or operation; solid red on two-stage boards means internal control faultNo fault on single-stage boards; failed control board on two-stage boardsNo action if heating normally; if solid red and dead, call a licensed HVAC technician
E0Communicating models: lockout from excessive ignition retries or flame recycles (three total)No gas to burners, bad igniter, coated flame sensor, or lost flame after lightingConfirm gas supply and thermostat call; ignition and gas faults need a licensed HVAC technician
E1Communicating models: low-stage pressure switch circuit closed at start of heating cycleLow-stage pressure switch contacts sticking, or short in pressure switch wiringCheck vent terminations are clear; switch replacement is licensed HVAC technician work
E2Communicating models: low-stage pressure switch circuit did not closeBlocked switch hose, blocked flue or intake, clogged drain, or weak inducerClear intake and vent terminations and check condensate drain; then a licensed HVAC technician
E3Communicating models: primary high limit open; insufficient air over the heat exchangerBlocked filter, restrictive ductwork, wrong blower speed, or failed blower motorReplace the filter and open registers and returns; repeat trips need a licensed HVAC technician
E5Communicating models: open control board fuse in the low-voltage circuitShort in 24-volt thermostat or component wiring blowing the 3-amp fuseCheck thermostat wiring for damage; fuse and short tracing by a licensed HVAC technician
E6Communicating models: weak flame; flame sense microamp signal is lowCoated or oxidized flame sensor, misaligned sensor, or lazy flame from gas pressureFlame sensor cleaning or replacement and gas checks need a licensed HVAC technician
E7Communicating models: problem with the igniter circuitImproperly connected or shorted igniter, poor unit ground, or board igniter relay faultIgniter and control board work is licensed HVAC technician work; do not touch the igniter element
E11R-32 models (display E11): open rollout switchFlame rollout from blocked flue passages, cracked heat exchanger, or failed inducerTurn the furnace off and do not reset; call a licensed HVAC technician immediately
EDCommunicating models (display Ed): manual-reset rollout switch is openBurner flames rolling out from blocked heat exchanger, misalignment, or displaced orifice plateTurn the furnace off and do not reset the rollout; call a licensed HVAC technician
EE0R-32 models (display EE0): lockout due to excessive retries or recyclesRepeated failed ignition or flame loss beyond the control's retry limitConfirm gas supply is on; repeated lockouts need a licensed HVAC technician, not repeated resets
EE1R-32 models (display EE1): pressure switch stuck closedSticking pressure switch contacts or shorted pressure switch circuitCheck vent terminations are clear; switch diagnosis is licensed HVAC technician work
EE2R-32 models (display EE2): pressure switch open; draft not provenBlocked vent or intake, clogged condensate, damaged switch hose, weak inducerClear vent and intake terminations and check the condensate drain first
EE3R-32 models (display EE3): open high limit switchRestricted airflow from clogged filter or blocked ducts overheating the furnaceReplace the filter and open all registers and returns; repeat trips need a licensed HVAC technician
EE4R-32 models (display EE4): flame detected when no flame should be presentLeaking gas valve, lingering burner flame, or shorted flame sensor signalTurn the furnace off; gas valve faults need a licensed HVAC technician immediately
EE5R-32 models (display EE5): open control board fuseShort in low-voltage wiring blowing the board fuseInspect thermostat wiring for nicks or rub-through; replacement by a licensed HVAC technician
EE6R-32 models (display EE6): low flame signalCoated flame sensor or weak flame from improper gas pressureFlame sensor and gas pressure work is licensed HVAC technician work
F02Not a standard Goodman consumer fault rendering — Goodman furnaces report faults with board LED blink patterns and, on communicating models, E-codes (E02 etc.). 'F02' is most likely a mis-read blink count or a communicating-thermostat rendering; decode via the model's chart.Blink-code miscountDiagnose the decoded code/symptom system with the model chart (ignition, pressure, limit families as applicable).
H6Not a standard published Goodman furnace fault code — decode via the model's LED blink pattern / communicating-system chart and the observed symptom.Thermostat/communicating display renderingDiagnose the decoded system (ignition, pressure switch, limit, flame sense — the Goodman families).
RAPID FLASHSingle-stage boards: reversed line polarity; two-stage boards: twinning wiring errorReversed 115-volt hot and neutral, poor ground, or incorrect twin-furnace wiringCorrect supply wiring and verify ground; work for a licensed HVAC technician or electrician
A code that is not in this table? Manufacturers add and retire codes between model years, and some displays abbreviate two-part codes. If your code is missing, note the full display exactly as shown (photograph it), check the tech sheet stored inside the machine, and search this site by the symptom — the fault family is usually identifiable from what the machine was doing when the code appeared.

How to reset / clear error codes on Goodman furnaces

Goodman furnaces report faults as LED blink patterns on older boards and as alphanumeric codes on the 7-segment displays of newer (and ComfortBridge/Bluetooth) models. Codes clear when the fault ends and a heat cycle completes; lockouts need the cause fixed plus a power cycle at the furnace switch.

How to diagnose any Goodman furnace code

Work the problem in this order — and stop at any point where gas, combustion or mains wiring is involved, because those belong to a licensed HVAC technician: (1) record the code exactly: count LED flashes slowly, twice, or photograph the alphanumeric display; (2) check the free things homeowners legitimately own: the thermostat is calling for heat, the furnace power switch and breaker are on, the filter is not clogged solid (a starved furnace overheats and locks out on limit codes), all vents and the return are open, and the condensate drain is not blocked on condensing models; (3) reset once — at the power switch, off for 30 seconds — then watch a full call for heat from the beginning: inducer, ignition, flame, blower, in that order; where the sequence stops is the fault family the code names; (4) a code that returns immediately is an active fault — do not keep resetting a lockout, especially any flame or limit code; (5) everything inside the burner compartment — flame sensor cleaning is the one grey area many manuals allow owners, but gas valves, burners, heat exchangers and control boards are professional work. If you smell gas at any point, leave and call the gas utility, not a helpline.

Blink codes, display codes and lockouts

Two generations of fault reporting live side by side on modern furnaces. Older and simpler boards report through a single LED: a repeating count of flashes, read slowly against the chart printed inside the blower door — that chart, for your exact model, outranks any list on the internet, including this one. Newer communicating furnaces show alphanumeric codes (the E-series in the table above) and store a fault history a technician can scroll. Both generations share the lockout idea: after a set number of failed attempts at the same step — ignition is the classic — the board stops trying for a period (often an hour, or until power is cycled) instead of cycling forever against a fault that could overheat or flood the burners with unburned gas. A furnace in lockout is not broken by the lockout itself; it is a furnace that has already failed the same step repeatedly and is waiting for someone to find out why.

Furnace codes are also seasonal in a way washer codes are not. The first cold snap produces a wave of ignition and flame codes from furnaces that sat idle all summer — oxidised flame sensors, spider-nested burners, pressure-switch hoses holding condensate from the cooling season. Deep-winter adds frozen condensate lines on high-efficiency models and intake/exhaust terminations blocked by snow or ice, which present as pressure-switch codes. A code that appears once, on the coldest night of the year, and never again has often met its cause already; a code that appears every cycle, in any weather, is a component asking to be tested.

The most searched Goodman furnace codes, in detail

9H — Not a standard published Goodman furnace fault

Like F02, '9H' doesn't appear in Goodman's standard published furnace fault systems. Where owners report 9H-style readings, they trace to communicating-thermostat displays or to mis-segmented characters. The honest route is identical: get the model number, read the board LED pattern properly (two full rounds), and diagnose by the observed symptom stage (inducer? ignition? flame? blower?). Goodman boards also store recent faults, which a technician can pull up directly.

Most likely cause: Display/thermostat rendering from a communicating system — The thermostat may show codes in its own format — its manual decodes them.

First check: Model number first; board LED count (two rounds); symptom stage noted.

If it keeps coming back: A repeatable pattern (same stage failure) is the best clue to record for a technician.

F02 — Not a standard Goodman consumer fault rendering

Goodman's fault language is (a) LED flashes on the control board for standard models and (b) E-prefixed codes on communicating (ComfortNet) systems. F02 doesn't appear as a standard Goodman furnace fault in either system. The likely truths: a blink pattern miscounted (count the flashes between pauses at the board sight glass), or an E02-style communicating code misread. Either way, the model number + its chart is the key — and the symptom (no heat? blower only? short cycles?) narrows the system regardless of the letters.

Most likely cause: Blink-code miscount — Board LEDs flash the code repeatedly with pauses — easy to miscount without watching two full rounds.

First check: Watch the board LED through the sight glass for two full pattern rounds and count carefully.

If it keeps coming back: If code-reading stays ambiguous, a technician reads the board's stored fault history in seconds.

H6 — Not a standard published Goodman furnace fault code

H6 follows the same pattern as F02/9H on Goodman equipment: it isn't in the standard published fault systems (LED blinks for standard models, E-codes for communicating ones). Treat any H-reading on a Goodman furnace as a prompt to do the two reliable things: count the control board's LED flashes through the sight glass across two full rounds, and observe which stage the furnace reaches before stopping (inducer → igniter glow → flame → blower). Stage + blink count identifies the system on any Goodman.

Most likely cause: Thermostat/communicating display rendering — Decoded by that thermostat's own manual.

First check: Board LED count (two rounds); stage observation; model number recorded.

If it keeps coming back: Consistent stage failure is the diagnostic gold — note exactly where the sequence stops.

Less common and model-specific codes

Search data shows owners also meet these codes on Goodman furnaces: 7P1, A11, B0, B1, B3, B4, E1C, ED8, F01, F03, F04, F09, F11, F4, F9, Fixes, Furnace, H9. They are not part of the core code list Goodman publishes for most models — several are series-specific, abbreviated display readings, or codes carried over from a sister platform — so we do not publish meanings for them rather than guess. Treat them by symptom: note what the machine was doing when the code appeared (filling, draining, heating, spinning), run one full power cycle (5 minutes off), and if the code returns, match the symptom to the closest documented family in the table above and check the tech sheet stored inside your machine for the model-specific definition.

Frequently asked questions

How to check goodman furnace error codes?

Goodman boards keep the last faults readable via the display/LED, and newer models expose fault history through the CoolCloudHVAC app and the onboard menu. The fault chart on the blower door remains the authority — Goodman reused similar-looking codes across board generations.

Related guides

Goodman Furnace hubAll Goodman error codes

Facts on this page were checked against manufacturer documentation: www.manualshelf.com · www.manualshelf.com · www.manualshelf.com · manuals.plus · iwae.com · www.goodmanmfg.com