Bryant Furnace Error Codes & Fix Guides

Bryant Furnace display showing CODE LIST — FixCode Guide error code graphic

All FixCode Guide coverage for Bryant furnace error codes: start with the complete code list, or jump to a deep-dive guide for a specific code. Everything is verified against Bryant manufacturer documentation.

Guides in this section

Bryant Furnace Error Codes List: Every Code ExplainedBryant Furnace 33 Error Code: Meaning, Causes & FixBryant Furnace 13 Error Code: Meaning, Causes & FixBryant Furnace Ignition Codes (14, 34): Meaning & FixesBryant Furnace Pressure Switch Codes (23, 31, 32): Meaning & FixesBryant Furnace 24 Error Code: Meaning, Causes & FixHow to Reset Bryant Furnace Error Codes

Most searched Bryant furnace codes

CodeMeaning
13Limit circuit lockout — lockout occurs if the limit or flame rollout switch is open longer than 3 minutes, or (variable-speed Bryant wording) 10 successive limit trips occurred during high-heat. The control will auto-reset after 3 hours. Bryant's label cross-refers every 13 to code 33 for the diagnosis.
24Secondary voltage fuse is open — the fuse protecting the control's 24-volt (secondary) circuit has opened because there is a short circuit in the secondary-voltage wiring. On the Evolution 987M the fuse is an automotive-type 3-amp fuse located on the control, and Bryant states the control LED will display status code 24 when the fuse needs to be replaced.
33Limit circuit fault — a limit switch or flame rollout switch in the limit circuit is open. The blower runs for 4 minutes or until the open switch remakes, whichever is longer; open longer than 3 minutes, the code changes to lockout 13; remade sooner, 33 keeps flashing until the blower shuts off. The rollout switch requires manual reset.