Home › Bosch › Bosch Water Heater › Bosch Tankless Water Heater Error Codes List: Every Code Explained

Bosch Tankless Water Heater Error Codes List: Every Code Explained

Bosch Water Heater display showing full error code list — FixCode Guide error code graphic

Every Bosch water heater error code we could verify against Bosch's own documentation — what it means, what usually causes it, and the first fix to try — in one table. Codes differ between model series, so treat your model's tech sheet as the final word.

Safety first. Before you start: unplug the appliance (or switch off its breaker) before opening any panel, and close the water taps before disconnecting hoses. Bosch's own manuals open with the boundary this page keeps: installation, gas and flue work, and the solutions in its error table are for a locally licensed professional. Owner-level work is external only — check the intake and exhaust terminations are clear, clean or replace the fan air filter, rinse the inlet water filter, confirm the condensate drain is not blocked or frozen on condensing models, confirm the gas cock is open, and reset once. Never open the burner compartment, adjust gas pressure or CO2, bypass a thermal fuse or ECO, or plug a dripping temperature-and-pressure relief valve. If you smell gas, turn off the gas shutoff, do not touch electrical switches, leave, and call the gas utility from outside. An over-temperature code (E1/E3/E4/E5) is also a scald warning: treat the water as unsafe on skin until the cause is fixed.

How to read and retrieve error codes on Bosch water heaters

Bosch tankless heaters report on a two-character LCD display — a letter plus a digit or a second letter (A7, C1, EA) — and the letter is the family: A codes are temperature sensors and cabinet heat, C codes are combustion air, venting, the fan and the water valves, E codes are over-temperature cut-offs, flame supervision and control-unit faults, and F codes are control, configuration and gas-path faults. Read the code exactly as shown, flashing or steady, and read it on the right generation: the Greentherm 9000 table and the older Therm table reuse letters with different meanings (A2 is an aquastat sensor on a Greentherm, the flue gas limiter on a Therm). Both generations keep a fault history you can quote to a technician — the Greentherm's FH menu lists the last 10 error codes with date and time, and the Therm diagnostic menu stores the last 10 failures at positions 1F through 10F.

The complete Bosch water heater error code list

CodeMeaningMost likely causeFirst fix
A0Greentherm 9000: water temperature sensors (outlet, heat exchanger, inlet) disconnected or damaged.A sensor wire connection is loose, damaged, or the sensor itself has failed.Licensed technician to check the sensor wire connections and replace the sensor or wiring if the code persists.
A1Greentherm 9000: air temperature inside the cabinet is above 158 F (70 C); the appliance reduces power to protect against overheating.External air above 140 F (60 C), or flue gas leaking inside the cabinet.Check the vent terminations are clear; a technician must check for flue leakage inside the appliance if it returns.
A2Greentherm 9000: external water temperature sensor / aquastat disconnected, damaged or not properly installed. Older Therm / C models: the flue gas limiter has activated (temperature above 230 F inside the cabinet) and the heater will not operate.Greentherm: sensor, its tank-well position or recirculation settings. Therm: blocked or damaged exhaust venting, or damaged heat-exchanger gaskets letting flue gas into the cabinet (Bosch US FAQ).Owner: confirm vent terminations are clear and unobstructed. Everything else — sensor position, limiter continuity, gaskets — is licensed-technician work.
A3Greentherm 9000: flue gases temperature sensor disconnected or damaged. Older Therm / C models: wire harness defect.Greentherm: failed flue sensor or its wiring. Therm: harness fault — Bosch specifies 115-120 ohm measured on the harness near the overmolding.Licensed technician to check the sensor or harness wire connections and replace the sensor, wiring or harness if it persists.
A4Greentherm 9000: air temperature sensor disconnected or damaged. Older Therm / C models: backflow temperature sensor defect — disconnected or short-circuited.Failed sensor or damaged/loose sensor wiring on the named sensor.Licensed technician to check the sensor connections and replace the sensor if the code persists.
A5Greentherm 9000: condensing unit flue temperature sensor disconnected or damaged.Failed condensing-unit flue sensor or its wiring.Licensed technician to check the sensor wire connections and replace the sensor or wiring if it persists.
A6Greentherm 9000: inlet cold water temperature sensor disconnected or damaged.Failed inlet sensor or its wiring.Licensed technician to check the sensor wire connections and replace the sensor or wiring if it persists.
A7Greentherm 9000: heat exchanger hot water temperature sensor disconnected or damaged. Older Therm / GWH models: hot (outlet) water temperature sensor fault — Bosch's E2 bulletin uses the swap test: if the fault follows the sensor, E2 becomes A7.Failed hot-side temperature sensor or its wiring.Licensed technician to check the sensor wire connections and replace the sensor if the code persists.
A8Greentherm 9000: outlet hot water temperature sensor disconnected or damaged.Failed outlet sensor or its wiring.Licensed technician to check the connections and replace the sensor or its wiring if the code persists.
A9Greentherm 9000: incorrect output power — too low.Low gas inlet pressure, or a water temperature / flow sensor connection problem.Licensed technician to check gas inlet pressure and the sensor wire connections; do not adjust gas settings yourself.
AAGreentherm 9000: condensing unit flue gases temperature above 392 F (200 C) and/or exhaust flue temperature above 145 F (63 C); the appliance reduces power to protect against overheating.Scale build-up in the heat exchanger (Bosch lists AA among its descaling codes), or a failing flue or inlet temperature sensor.Have the appliance descaled by a licensed technician; sensors are checked and replaced if the code persists.
ADGreentherm 9000: flue blockage detected during startup due to insufficient combustion air; power is derated. Bosch's US FAQ stresses AD is also an informational derate notice, not only a fault: the unit still produces hot water at reduced capacity.Blocked air intake or exhaust, clogged fan air filter, long vent run, or altitude above 2,000 ft.Owner: check air openings and exhaust termination for obstructions and clean or replace the air filter, then reset once (hold ON/OFF 3 seconds). If it persists, a technician performs gas and air tuning.
BBGreentherm 9000: fan calibration triggered due to missed ignitions.The control is re-learning fan behaviour after ignition failures — usually a gas pressure or tuning problem underneath.Licensed technician to check gas inlet pressure and perform gas and air tuning; treat the underlying EA ignition fault, not the calibration.
BCGreentherm 9000: successive fan calibration with similar learned values.Repeated fan calibrations are converging on the same values — the combustion setup still is not right.Licensed technician to check gas inlet pressure and perform gas and air tuning.
C1Greentherm 9000: excessive flue blockage detected during startup due to insufficient combustion air; the appliance shuts down for safety.Blocked intake or exhaust venting, or a clogged air filter (Bosch section 8.8 groups C1 with C2, CF and CE as venting-obstruction codes).Owner: clear any vent obstruction, clean or replace the air filter, reset once (hold ON/OFF 3 seconds). If it persists, a technician performs gas and air tuning.
C2Greentherm 9000: excessive flue blockage detected during startup due to insufficient combustion air; the appliance shuts down for safety (listed with C1 in the manual table).Blocked intake or exhaust venting, or a clogged air filter.Owner: clear any vent obstruction, clean or replace the air filter, reset once. If it persists, a technician performs gas and air tuning.
C3Greentherm 9000: the flow sensor does not detect water recirculation.Recirculation pump or its connections, or a blockage in the recirculation circuit.Licensed technician to check the pump and connections and clear any recirculation blockage.
C5Greentherm 9000: bypass water valve disconnected or damaged.Failed bypass valve or its wiring.Licensed technician to check the valve wire connections, replace the valve if needed, then run the bypass valve calibration.
C7Greentherm 9000: fan disconnected or damaged.Failed combustion fan or its wiring.Owner: reset once (hold ON/OFF 3 seconds). If it persists, a technician checks the fan connections and replaces the fan or wiring.
C8Greentherm 9000: main water valve disconnected or damaged.Failed main water valve or its wiring.Licensed technician to check the valve wire connections and replace the valve or wiring if it persists.
C9Greentherm 9000: barometric pressure sensor damaged.Failed barometric pressure sensor, which lives in the electronic control unit.Owner: reset once (hold ON/OFF 3 seconds). If it persists, the control unit is replaced by a technician.
CAGreentherm 9000: water flow above 9.2 gpm.Excessive flow or pressure (above the 150 psi limit), or air in the hydraulic circuit.Licensed technician to purge air from the circuit, fit a flow restrictor if needed, and confirm pressure stays under 150 psi.
CEGreentherm 9000: excessive flue blockage detected during operation due to excessive pressure on the siphon (condensate trap); the appliance shuts down for safety.Blocked condensate siphon/drain, blocked venting, or a clogged air filter (Bosch groups CE with the venting-obstruction codes).Owner: check the condensate drain is not blocked or frozen, clear vent obstructions, clean the air filter, reset once. If it persists, a technician performs gas and air tuning.
CFGreentherm 9000: excessive flue blockage detected during operation due to insufficient combustion air; the appliance shuts down for safety.Blocked intake or exhaust venting during the burn, or a clogged air filter.Owner: clear vent obstructions, clean or replace the air filter, reset once. If it persists, a technician performs gas and air tuning and Bosch support is contacted for dusty-area installs.
E0Greentherm 9000: electronic control unit internal error.An internal fault in the control unit itself.Owner: reset once (hold ON/OFF 3 seconds). If it persists, the control unit is replaced by a technician.
E1Water temperature too high: Greentherm 9000 — hot water above 194 F (90 C), burner cut off to prevent scalding, reactivates after cooling. Older Therm models — over-temperature detected by the outlet sensor, above 185 F.Scale build-up restricting flow through the heat exchanger, or a failing outlet temperature sensor.Let the unit cool; have it descaled by a technician if hard water is present, and the sensor checked. Do not keep resetting an over-temperature code.
E2Older Therm / GWH models (not used on Greentherm 9000): cold (inlet) water temperature sensor fault.Failed, corroded or badly seated inlet sensor, or its wiring (Bosch bulletin TWH-G2-35 documents the sensor swap test).Licensed technician to inspect, clean and reposition the sensor, and replace it if the fault does not follow the swap test.
E3Greentherm 9000: flue gases temperature above 167 F (75 C), or 2 minutes above 145 F (63 C); burner cut off to prevent overheating. Older Therm condensing models: exhaust temperature sensor over 194 F — the appliance closes the burner and locks.Scale build-up in the heat exchanger (Bosch lists E3 among its descaling codes), or a failing flue/exhaust temperature sensor.Have the appliance descaled by a licensed technician, reset once; the sensor is checked against Bosch's resistance chart and replaced if out of specification.
E4Greentherm 9000: air temperature inside the cabinet above 176 F (80 C), or 2 minutes above 158 F (70 C); burner cut off to prevent overheating. Older Therm models: backflow temperature sensor over 309 F — burner closes and locks (non-volatile).Greentherm: flue gas leaking inside the cabinet, or a failing cabinet air sensor. Therm: venting outside specification — long runs, too many elbows, blocked vent — or a disconnected secondary fan.Licensed technician: check for internal flue leakage and venting compliance, reset once, and replace the sensor if out of specification. Do not run the heater with a standing E4.
E5Greentherm 9000: condensing unit flue gases temperature above 428 F (220 C), or 2 minutes above 392 F (200 C); burner cut off to prevent overheating.Scale build-up in the heat exchanger, or a failing condensing-unit flue sensor.Have the appliance descaled by a licensed technician, reset once; sensor checked and replaced if out of specification.
E7Greentherm 9000: electronic control unit internal error.An internal fault in the control unit itself.Owner: reset once (hold ON/OFF 3 seconds). If it persists, the control unit is replaced by a technician.
E8Greentherm 9000: error during the ionization test — electronic control unit internal error.The control unit's flame-ionization self-test failed.Licensed technician: Bosch's table directs replacement of the electronic control unit.
E9Greentherm 9000: thermal fuse broken.The thermal fuse has opened, typically after an overheat event in the cabinet.Licensed technician to replace the thermal fuse and find the overheat cause; a fuse is never bypassed.
EAIgnition failure: no flame ionization detected with water flow. Bosch's US FAQ: the heater tried to ignite the burners three times when water flow was sensed, but the burners did not ignite.Gas shutoff closed, air in the gas line, wrong gas type (LP model on natural gas or vice versa), low gas pressure, undersized gas piping, or dirty/damaged spark electrodes (Bosch FAQ list).Owner: confirm the gas shutoffs are open and other gas appliances work, then reset once and run a hot tap to purge air. Gas pressure, electrodes and tuning are licensed-technician work (Bosch bulletin TWH-G2-09).
EBGreentherm 9000: electronic control unit internal error.An internal fault in the control unit itself.Owner: reset once (hold ON/OFF 3 seconds). If it persists, the control unit is replaced by a technician.
ECFlame lost during operation (ionization failure while burning). Bosch's Greentherm manual groups EA and EC: both can appear if combustion is not properly set.Improper gas supply conditions — pressure or gas composition — wrong gas type selected, or venting problems damaging the flame sensor rod.Owner: confirm gas supply is on, reset once. A technician verifies gas type and pressure and performs gas and air tuning if it persists.
EEGreentherm 9000: gas valve modulation solenoid disconnected.Loose gas valve wire connection, or a failed gas valve, wiring or control unit.Licensed technician to check the gas valve wire connection; gas valve replacement is followed by gas and air tuning. Never open the gas path yourself.
EFGreentherm 9000: wrong gas connected — LP instead of natural gas — for the appliance's current configuration.The connected fuel does not match the configured gas type.Stop using the heater and call a licensed technician to verify the gas type and configuration; gas conversion is professional work.
F2Greentherm 9000: electronic control unit internal error.An internal fault in the control unit itself.Owner: reset once (hold ON/OFF 3 seconds). If it persists, the control unit is replaced by a technician.
F3Greentherm 9000: electronic control unit internal error (configuration may be required).Internal control fault, or the appliance configuration (region, power, type, gas type) was lost or never set.Owner: reset once. If it persists, a technician reconfigures the appliance, performs the automatic combustion adjustment, or replaces the control unit.
F7Greentherm 9000: electronic control unit internal error.An internal fault in the control unit itself.Owner: reset once (hold ON/OFF 3 seconds). If it persists, the control unit is replaced by a technician.
F8Greentherm 9000: electronic control unit internal error.An internal fault in the control unit itself.Owner: reset once (hold ON/OFF 3 seconds). If it persists, the control unit is replaced by a technician.
F9Greentherm 9000: gas valve driver internal fault.Fault in the control unit's gas valve driver circuit, or gas valve wiring.Licensed technician to check the gas valve wire connections and replace the wiring or control unit if it persists.
FAGreentherm 9000: gas leakage in the gas path — the gas valve or gas manifold shutoff valves are not sealing.A leaking gas valve or manifold shutoff valve inside the appliance.Stop using the heater, turn off the gas shutoff, and call a licensed technician or the gas utility: Bosch directs replacement of the gas valve and/or manifold, followed by gas and air tuning.
FCGreentherm 9000: control buttons pressed for more than 30 seconds. A status report, not a component fault.A button held or stuck down for over 30 seconds.Release the button; clear anything resting against the control panel.
A code that is not in this table? Manufacturers add and retire codes between model years, and some displays abbreviate two-part codes. If your code is missing, note the full display exactly as shown (photograph it), check the tech sheet stored inside the machine, and search this site by the symptom — the fault family is usually identifiable from what the machine was doing when the code appeared.

How to reset / clear error codes on Bosch water heaters

Bosch documents two resets, one per generation. On Greentherm 9000 models, remove an error code by pressing and holding the ON/OFF button for more than 3 seconds (a long press); the manual adds that some codes can also be cleared by shutting off the water flow and turning it back on — the C-family note limits that method to 3 times per hour. On the older Therm / C generation there is a dedicated reset button: 'To remove error code from the display, press the reset button.' Both resets only clear the display — Bosch's tables pair every reset with its cause check, because a standing fault re-reports, and several Greentherm codes (the over-temperature E family, FA gas leakage) must never be repeatedly reset and run. Reset once, after the external checks, then run one hot tap and watch which stage the code returns at.

How to diagnose any Bosch water heater code

Work the problem in this order — and stop wherever gas piping, the burner compartment, venting or the temperature-and-pressure relief valve begins, because those belong to a licensed technician: (1) record the report exactly — a counted LED flash pattern, a numeric display code, or a smart-control alarm are three different languages, and a photograph or video beats a memory of any of them; (2) establish the water story: is there no hot water at all, water that runs cold mid-draw, or water but with a code — tankless codes split into ignition, flame, airflow/venting, flow and temperature families, and tank codes into ignition, sensor and control families, and the family picks the checks; (3) run the owner-level external checks for that family first: power and the unit's switch, the gas cock fully open, intake and exhaust terminations clear of snow, nests and debris, the inlet water filter or screen rinsed (tankless), the condensate trap and drain not blocked or frozen (condensing models), and on tank models the status light read before anything is reset; (4) reset once, the way the brand documents, and run hot water at one tap while you watch — a code that returns at the same stage (fan start, ignition click, flame light, sustained burn) is an active fault naming its stage, not a glitch; (5) everything past that line — flame sensors and igniters inside the burner, gas valves, heat exchangers, control boards — is professional work with the gas supply and a meter involved. Two standing cautions: never plug or cap a dripping T&P relief valve (it is reporting pressure or temperature, and it is the tank's last safety device), and treat any gas smell as an emergency — leave and call the gas utility. Scalding is the quiet hazard in every reset: a control fault that lets outlet temperature drift high is a reason to stop using the water on skin until the code is resolved.

Two Bosch generations, one alphabet: read the code on the right platform

Bosch has sold two tankless generations in North America under overlapping names, and they share a code alphabet without sharing all of its meanings. The current platform is the Greentherm 9000 series — T9900 SE and T9900i SE, T9800 SE and the outdoor T9800 SEO, in 160,000 and 199,000 BTU sizes — condensing heaters with a colour display, auto-tuning combustion, an optional fan air filter, and on the i models a built-in recirculation pump. Behind it sits the older Therm generation — Therm 830 ES, 920 ES and 940 ES, the condensing C 1050 and C 1210 ES/ESC, and the GWH models those designs descend from — with a simpler two-character LCD, a dedicated reset button and a Program key. Both generations write codes as a letter plus a digit or second letter, and both sort them into the same broad families. But the generations were programmed separately, and at least six letters changed meaning between them: A2, A3, A4, A7, E3 and E4 do not mean the same thing on a Greentherm as on a Therm. Bosch's own US FAQ demonstrates the trap — its A2 answer describes the older flue gas limiter, while the Greentherm manual's A2 is an external aquastat sensor that has nothing to do with flue gas. The hardware tells the generations apart at a glance if you know where to look: Greentherm models carry their rating as T9900 or T9800 on the cover and run their menus from a colour display, while Therm models carry the 830/920/940 ES names and the older control layout with its separate reset and Program buttons. The table on this page therefore scopes every colliding row to its generation, and the model name is part of every lookup: quote code and model together, in any search and any service call, because each half alone can send you to the wrong generation's table and a confident, wrong repair.

The A family: a map of the heater's temperature sensors

On a Greentherm 9000, the A codes are the temperature-sensor census. The heater watches its water and air with a chain of named sensors — Bosch's component list numbers them: outlet hot water sensor [17], heat exchanger hot water sensor [19], inlet cold water sensor [20], flue gases sensor [15], condensing unit flue sensor [16], cabinet air sensor [18], and the external aquastat [21] that reads a storage tank or recirculation loop — and the A family reports them in order: A0 is the group report (water temperature sensors disconnected or damaged), A2 the external aquastat, A3 the flue gases sensor, A4 the cabinet air sensor, A5 the condensing unit flue sensor, A6 the inlet sensor, A7 the heat exchanger sensor and A8 the outlet sensor. Almost every A solution in Bosch's table is the same sentence — check the sensor wire connections; replace the sensor and/or wire connections if the problem persists — because an A code is a continuity report, not a temperature report: the control can no longer trust a reading it needs, so it stops rather than fire blind. Two A codes break the pattern. A1 is a genuine temperature event — cabinet air above 158 F (70 C), with the appliance derating to protect itself, caused by very hot ambient air or flue gas leaking inside the cabinet — and A9 is an output report, power too low, pointing at gas inlet pressure or the sensor chain. On the older Therm generation the A family is shorter and partly different: A2 is the flue gas limiter (cabinet temperature above 230 F), A3 a wire harness defect Bosch tests at 115–120 ohms, A4 the backflow sensor, and the hot-sensor fault that Greentherm calls A7/A8 is reached there through the E2 bulletin swap test. Same letters, different map — the generation decides.

The C family: combustion air, venting, the fan and the water valves

If the A family is the heater listening to its sensors, the C family is the heater reporting on its breathing and its plumbing. The blockage codes are the heart of it, and Bosch splits them by when the blockage is proven and how bad it is: AD is a derate — flue blockage detected during startup, power reduced, the unit still runs (Bosch's US FAQ calls AD an informational code, and lists its causes as insufficient air supply, blocked intake or exhaust, a clogged fan air filter, long vent runs and altitude over 2,000 ft). C1 and C2 are the same startup detection at shutdown level — excessive blockage, appliance off for safety. CE and CF are the operating pair: blockage proven during the burn, CE specifically from excessive pressure on the condensate siphon, CF from insufficient combustion air. Bosch's troubleshooting section groups C1, C2, CF and CE together and gives them one owner recipe — verify there are no venting obstructions, clean or replace the air filter, reset — which is why the external terminations and the fan filter are the first checks for any C code. Around the blockage codes sit the component reports: C7 the fan disconnected or damaged, C3 the flow sensor seeing no recirculation, C5 the bypass water valve and C8 the main water valve disconnected or damaged, C9 a damaged barometric pressure sensor (whose fix is the control unit), and CA a plain flow report — water flow above 9.2 gpm, answered with purging air from the circuit and checking pressure against the 150 psi limit. Read a C code as a sequence: is it a derate or a shutdown, at startup or during operation, and is it about air in, gas out, or water through? Those three answers pick the checks.

The E and F families: over-temperature cut-offs, flame supervision and the control itself

The E family mixes three different kinds of seriousness, and telling them apart matters more than the digits. First are the over-temperature cut-offs, where the heater stops the burner to protect itself or you: E1 is water temperature — above 194 F (90 C) on a Greentherm, above 185 F at the outlet sensor on a Therm — with the burner cut off against scalding and reactivation only after cooling; E3, E4 and E5 are the flue and cabinet versions (flue gases above 167 F, cabinet air above 176 F, condensing flue gases above 428 F, each with a two-minute lower threshold), and Bosch's own descaling section names E3 — with AA and A5 — as a scale code, because a scaled heat exchanger runs its flue side hot. E9 is the thermal fuse, broken: a one-time safety device that is replaced, never bypassed. Second is flame supervision: EA, ignition failure — no flame ionization detected with water flow, which Bosch's FAQ quantifies as three failed ignition attempts — and EC, flame lost during operation, with Bosch grouping the pair as a combustion-setting problem (gas pressure, gas type, tuning). Third is the control reporting on itself: E0, E7 and EB are electronic control unit internal errors, E8 an ionization-test error whose Bosch solution is control replacement, and EE and EF pull the gas path back in — the gas valve modulation solenoid disconnected, and the wrong gas connected for the configuration. The F family is the control's second drawer: F2, F3, F7 and F8 are further internal errors (F3 allows that configuration may be required), F9 is the gas valve driver, FC is housekeeping — buttons pressed over 30 seconds — and FA is the family's emergency: gas leakage in the gas path, the valve or manifold not sealing, answered by shutting the heater down and replacing the valve or manifold. An FA is never a reset-and-watch code.

Diagnosis order on a Bosch: external air and water first, one reset, then the stage test

Work a Bosch code in the order the heater itself experiences a call for hot water, and stop at the line Bosch draws around licensed work. Start by recording the report exactly — code, flashing or steady, model generation, and what the taps were doing — and, on a Greentherm, open the FH failure-history menu: the last 10 codes with dates often show whether today is a first offence or the end of a pattern (the Therm stores the same history at 1F–10F in its diagnostic menu). Then run the external checks that match the family. For C codes and AD: walk the venting — intake and exhaust terminations clear of snow, nests and debris, no crushed or disconnected runs visible — and clean or replace the fan air filter. For ignition codes (EA, EC, BB, BC): confirm every manual gas shutoff is open and another gas appliance works, which separates a house supply problem from a heater problem without touching the gas path. For flow and temperature complaints: rinse the inlet water filter screen — Bosch lists it in annual maintenance and in its low-flow troubleshooting — and check the condensate trap and drain on condensing models, which is also the CE check. Only then reset, once, the documented way for your generation (Greentherm: hold ON/OFF for more than 3 seconds; Therm: the reset button), and run one hot tap while you watch and listen: fan start, ignition clicks, flame established, sustained burn. The stage at which the code returns is the diagnosis the code alone could not give you — a C code at fan start is air, an EA after clicking is gas or electrodes, an E code minutes into a long draw is heat and scale. Everything past that stage test — gas pressure and tuning, electrodes, sensors inside the cabinet, valves, the control unit — is the licensed technician's half of Bosch's own table, and quoting the code, the generation and the stage it failed at is the most useful thing an owner can hand over.

Less common and model-specific codes

Search data shows owners also meet these codes on Bosch water heaters: A-Family, C-Family, E/F-Family. They are not part of the core code list Bosch publishes for most models — several are series-specific, abbreviated display readings, or codes carried over from a sister platform — so we do not publish meanings for them rather than guess. Treat them by symptom: note what the machine was doing when the code appeared (filling, draining, heating, spinning), run one full power cycle (5 minutes off), and if the code returns, match the symptom to the closest documented family in the table above and check the tech sheet stored inside your machine for the model-specific definition.

Related guides

Bosch Water Heater hubAll Bosch error codes

Facts on this page were checked against manufacturer documentation: www.bosch-homecomfort.com · www.bosch-homecomfort.com · www.bosch-homecomfort.com · www.bosch-homecomfort.com · www.prowaterheatersupply.com · www.prowaterheatersupply.com · www.globaltowne.com